User's Guide

4-14 Configuring Your Server
Server
Option Parameter Description Your Setting
System
Management
System Management submenu is
displayed.
Console
Redirection
Console Redirection submenu is
displayed.
Assert NMI on
PERR
Disabled
[Enabled]
Indicates whether PCI PERR is
supported or not.
Assert NMI on
SERR
Disabled
[Enabled]
Indicates whether PCI SERR is
supported or not.
Post Error Pause Disabled
[Enabled]
Indicates whether POST is aborted once
at the end of POST if an error occurs
during the execution of POST.
AC LINK Stay Off
[Last State]
Power On
Indicates the AC LINK function. Shows
the state of the power of the server.
[ ]: Factory-set
IMPORTANT: To power on the server from the UPS (Uninterruptible
Power Supply), select [Server] - [AC Link] - [Power On].
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK."
Setting of AC LINK
System status before AC power off
Stay Off Last State Power On
Operating Off On On
Aborting (DC power being off also) Off Off On
Forced shutdown Off Off On
* Press the power switch continuously for four seconds or longer. This forcibly turns off the
power.