User's Guide

2-16 General Description
Virtual LCD indications when STATUS lamp is flashing amber
On-screen message Description Action
Mem Reconfigured The memory is degraded. 1. Check the installation status of
the DIMM.
2. Replace the DIMM.
Mem Err Disable Correctable memory error frequently
occurs.
CPU Reconfigured The CPU is degraded. 1. Check the installation status of
the CPU.
2. Replace the CPU.
HDD X Fault An error was detected in hard disk
drive in slot X. X denotes the slot
number with 1-origin that contains
the failed hard disk drive.
Check the hard disk drive.
E-Keying Error In the Blade Enclosure, combination
of installation locations of CPU
blade, mezzanine card, and switch
module is not correct. Thus, an
unconformity of interface signal was
detected and the CPU blade failed
to power on.
Refer to the User's Guide of the
Blade Enclosure for the correct
installation locations.
Location Error In the Blade Enclosure, the
installation location of CPU blade is
incorrect, or the installation locations
of the fan and CPU blade are
incorrect. Thus, the CPU blade
failed to power on.
Refer to the User's Guide of the
Blade Enclosure to check if the CPU
blade is installed in the correct
location.
Check the installation locations of
the fan and CPU blade.
Cooling Error In the Blade Enclosure, the number
of fans installed is insufficient or the
installed fan is faulty. Thus, the CPU
blade failed to power on due to
insufficient cooling power.
Check if the fans in the Blade
Enclosure work normally.
Check if the heat sink of the CPU
blade works normally.
Refer to the User’s Guide of the
Blade Enclosure to make sure that a
sufficient number of fans are
installed.
Check if the fans and CPU blades
are installed in the correct locations.
Check if the ambient temperature of
the installation location satisfies the
operating conditions.
Proc1 Therm % 07 A high temperature warning was
detected in CPU#1.
Proc2 Therm % 07 A high temperature warning was
detected in CPU#2.
AmbientTempAlm07 A high temperature warning was
detected in CPU unit.
DAS AirTempAlm07 A high temperature warning was
detected in storage unit.
AmbientTempAlm00 A low temperature warning was
detected in CPU unit.
Check if the ambient temperature of
the installation location satisfies the
operating conditions.
DAS AirTempAlm00 A low temperature warning was
detected in storage unit.
Battery Alm XX A battery voltage warning was
detected.
XX=07: Upper limit warning
XX=00: Lower limit warning
1. Check the installation status of
the battery.
2. Replace the battery.