4-20 Configuring Your Server
See the table below for the options and their descriptions:
Option Parameter Description Your Setting
FRB-2 Policy Disable FRB2 Timer
[Disable BSP]
Do Not Disable BSP
Retry 3 Times
Set the policy to be applied to FRB
level 2 timer.
Boot Monitoring [Disabled]
5 minutes
10 minutes
15 minutes
20 minutes
25 minutes
30 minutes
35 minutes
40 minutes
45 minutes
50 minutes
55 minutes
60 minutes
Specify whether the boot
monitoring feature is enabled or
disabled and the timer value.
To use this feature, install NEC
ESMPRO Agent. Do not use this
feature if the system is booted
from the operating system without
NEC ESMPRO Agent installed.
Set this item to "Disabled" if
ARCServe uses the Disaster
Recovery Option.
Thermal Sensor Disabled
[Enabled]
Specify whether the temperature
sensor monitoring function is
enabled or disabled.
BMC IRQ Disabled
[IRQ 11]
Specify the IRQ of the BMC.
Post Error Pause Disabled
[Enabled]
Specify whether POST ishalted if
an error occurs.
AC-LINK Stay Off
[Last State]
Power On
Specify the AC-LINK feature.
Select the state when the power of
the CPU blade is restored. See
the table below.
[ ]: Factory-set
NOTE:
Refer to the User's Guide of the Blade Enclosure for more
information on the AC-LINK feature.
The table below shows the system status when AC power to the server is turned off and then
restored:
System status before AC power off
Setting of AC-LINK
Stay Off Last State Power On
Operating Off On On
Shutdown (DC power off) Off Off On
Forced shutdown* Off Off On
* Press the POWER switch for four seconds or longer. This forcibly turns off the power.