User's Guide

General Description 2-11
On-screen message Description Action
Battery Alm XX A battery voltage alarm was
detected.
XX=09: Upper limit alarm
XX=02: Lower limit alarm
1. Check the installation status of
the battery.
2. Replace the battery.
Proc1 Vccp AlmXX
Proc2 Vccp AlmXX
BB FSBvtt Alm XX
BB DIMMvtt AlmXX
BB +1.2v Alm XX
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +3.3v Alm XX
BB +5v Alm XX
BB +1.2vs Alm XX
BB +1.5vs Alm XX
BB +1.25vs AlmXX
BB +3.3vs Alm XX
BB +5vs Alm XX
BB +12vs Alm XX
A voltage alarm was detected.
XX=09: Upper limit alarm
XX=02: Lower limit alarm
Replace the CPU blade.
Virtual LCD indications when STATUS lamp is flashing amber
On-screen message Description Action
Mem Reconfigured The memory is degraded. 1. Check the installation status of
the DIMM.
2. Replace the DIMM.
Mem Err Disable Correctable memory error frequently
occurs.
CPU Reconfigured The CPU is degraded. 1. Check the installation status of
the CPU.
2. Replace the CPU.
E-Keying Error In the Blade Enclosure, combination
of installation locations of CPU
blade, mezzanine card, and switch
module is not correct. Thus, an
unconformity of interface signal was
detected and the CPU blade failed
to power on.
Refer to the User's Guide of the
Blade Enclosure for the correct
installation locations.
Location Error In the Blade Enclosure, the
installation location of CPU blade is
incorrect, or the installation locations
of the fan and CPU blade are
incorrect. Thus, the CPU blade
failed to power on.
Refer to the User's Guide of the
Blade Enclosure to check if the CPU
blade is installed in the correct
location.
Check the installation locations of
the fan and CPU blade.