User's Manual

4-18 Configuring Your Modular Server
Option Parameter Description Your Setting
Thermal Sensor Disabled
[Enabled]
Specify whether the temperature
sensor monitoring feature is
enabled or disabled. If a thermal
error is detected with this item
being set to "Enabled", the system
stops at the end of POST.
BMC IRQ Disabled
[IRQ 11]
Specify whether to assign IRQ for
BMC (Baseboard Management
Controller).
Post Error Pause Disabled
[Enabled]
Specify whether POST is aborted
once at the end of POST if an error
occurs during the execution of
POST.
AC-LINK Shamrock-G
Stay Off
[Last State]
Power On
Specify the AC-LINK feature.
Shows the system status when the
AC power is supplied again to the
modular server. See the table
below.
Power ON Delay
Time
Default [t1] (s)
[t1-255] (s)
Specify the power-on delay time
between 1 and 255 seconds. This
option is available only when
"Power On" or "Last State" is
specified for AC LINK.
Platform Event
Filtering
Disabled
[Enabled]
Specify whether the Platform
Event Filtering feature of the
Baseboard Management
Controller (BMC) is enabled or
disabled.
[ ]: Factory-set
The table below shows the operation when the AC power to the modular server is turn off once and
then on again, depending on the setting of "AC-LINK".
Setting of AC-LINK
System status before AC power off
Stay Off Last State Power On
Operating Off On On
Aborting (DC power being off also) Off Off On
Forced shutdown* Off Off On
* Press the POWER/SLEEP switch continuously for four seconds or longer. This forcibly turns off
the power.