N8800-063E/064E NEC Express5800/320Lc/320Lc-R User's Guide (Setup) 1st Edition 12-2004 856-124610-001-A
PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs and related materials, is the valuable property of NEC Corporation (NEC) and /or its licensors. NEC and/or its licensors, as appropriate, reserve all patent, copyright and other proprietary rights to this document, including all design, manufacturing, reproduction, use, and sales rights thereto, except to the extent said rights are expressly granted to others.
Keep this User's Guide handy for quick reference when necessary. Safety Indications To use NEC Express5800 Series safely, follow the instructions in this User's Guide. This guide explains components that pose a danger, types of dangers caused by failing to follow the instructions, and actions taken to prevent them; such components are labeled warning. This guide and warning labels use “WARNING” and “CAUTION” to indicate a danger depending on the degree.
Symbols and its descriptions used in this User’s Guide and warning labels are as follows: Attention Indicates a risk of an electric shock. Indicates a risk of an injury due to heat. Indicates a risk of catching your fingers. Indicates a risk of a fire or smoke. Indicates a general precaution or warning that are not defined herein. Indicates a risk of losing eyesight due to laser beam. Indicates a risk of an injury or damage to physical assets due to a hazardous material.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Trademarks NEC EXPRESSBUILDER, NEC ESMPRO, and NEC Express5800/ft series are trademarks of NEC Corporation. Stratus is a registered trademark of Stratus Technologies Bermuda Ltd. Microsoft, Windows, Windows Server, Windows NT, and MS-DOS are registered trademarks of Microsoft Corporation in the United States and other countries. Intel and Pentium are registered trademarks of Intel Corporation.
i Preface Welcome to the NEC Express5800/ft series. NEC Express5800/ft series is a “fault-tolerant (ft)” server focusing on “high reliability” in terms of fault-tolerance, in addition to “high performance,” “scalability,” and “general versatility” provided by NEC Express5800 series.
ii About This User’s Guide This User's Guide helps a user to properly setup and use the product. Consult this guide when you set up the product. Keep this manual and the separate volume of User’s Guide handy. This User's Guide is intended for users who have a good knowledge on the basic use of Windows operating systems and general I/O devices such as a keyboard and mouse.
iii Additional symbols The following symbols are used throughout this User's Guide in addition to the caution symbols described at the beginning.
iv Contents Preface.................................................................................................................................................i About This User’s Guide ..................................................................................................................ii How to Use This User's Guide........................................................................................................ii Additional symbols ..................................................
v 2-1: Initialize Hard Disks.............................................................................................................4-6 2-2: Prepare NEC Express5800/ft series......................................................................................4-8 Step 3: Disable Boot Monitoring Function ................................................................................4-11 Step 4: Start the ft series Setup...................................................................................
vi System Repair.................................................................................................................................6-2 Preparation ...................................................................................................................................6-2 Starting up Recovery Console......................................................................................................6-4 Updating the System .............................................................
Chapter 1 Before Using This chapter includes information necessary for proper and safe operation of the server, the main unit and its accessories. Go through this chapter before you start setup of the product.
1-2 Before Using Notes for Safe Handling The following section describes necessary information to use the product properly and safely. Warning Labels Warning labels are placed in certain parts of the system so that the user stays alert to possible risks (Do not remove or damage these labels). If some label is missing, about to peel off, or illegible, contact your sales agent. The figures below show locations of the labels on the server.
Before Using 1-3 Label A Label B Label C Label E Label D
1-4 Before Using Rack-mount Model Label A Label B Label B Label C Label C Label D Label E Label D Label E
Before Using 1-5 Label A 为防止触电及火灾,关于模块/线缆的安装/拆卸,请参考操作说明书。 Label B 请小心不要夹住或碰伤手指。 设备运行时以及刚切断电源后,硬盘表面温度会很高,请一定注意。 对 CPU 模块、PCI 模块、电源模块以外的部件进行维护时,为防止触电,请拔下所有电源线和外接线缆。 有的部件可能会达到高温,请注意待其冷却之后再接触。 请一定注意不要把螺丝掉落在主机内部,否则可能会引起火灾。 Label C 只有维护员方可对本设 备进行拆卸, 否则可能 会引起触电等事故。 Label E Label D
1-6 Before Using PCI/CPU Modules PCI Module Label A CPU Module Label A Label A Label A
Before Using 1-7 Precautions for Safety This section provides precautions for using the server safely. Read this section carefully to ensure proper and safe use of the server. For symbol meanings, see "Safety Indications" described in the previous section. General WARNING Do not use the equipment in an operation where human lives are involved or high reliability is required.
1-8 Before Using CAUTION Prevent water or foreign objects from getting into the equipment. Do not let water or foreign objects (e.g., pins or paper clips) enter the equipment. There is a risk of a fire, electric shock, and breakdown. When such things accidentally enter the equipment, immediately turn off the power and unplug the cord. Contact your sales agent instead of trying to disassemble it yourself.
Before Using 1-9 Use of Power Supply and Power Cord WARNING Do not handle a power plug with a wet hand. Do not plug/unplug a power cord with a wet hand. There is a risk of an electric shock. Do not connect the ground wire to a gas pipe. Never connect the ground wire to a gas pipe. There is a risk of a gas explosion. CAUTION Do not plug the cord in a nonconforming outlet. Use a wall outlet with specified voltage and power type. There is a risk of a fire or current leakage.
1-10 Before Using CAUTION Do not use nonconforming power cords. Use the power cords specified by NEC. If the rated current is exceeded, there is a risk of a fire. You also have to observe the following prohibitions to prevent damage to the cords. Do not pull on the cord. Do not pinch the cord. Do not bend the cord. Keep chemicals away from the cord. Do not twist the cord. Do not place any object on the cord. Do not bundle several cords. Do not alter, modify, or repair the cord. Do not staple the cord.
Before Using 1-11 Installation, Relocation, Storage and Connection WARNING Disconnect the power cord(s) before installing or removing the equipment. Be sure to power off the equipment and unplug its power cords from the wall outlet before installation/relocation. All voltage is removed only when the power cords are unplugged. CAUTION Do not hold the front bezel to lift the equipment. The equipment weighs approximately 70 kg (depending on its hardware configuration).
1-12 Before Using CAUTION Do not connect any interface cable with the power cord of the server plugged to a power source. Make sure to power off the server and unplug the power cord from a power outlet before installing/removing any optional internal device or connecting/disconnecting any interface cable to/from the server.
Before Using 1-13 Cleaning and Handling of Internal Devices WARNING Do not disassemble, repair, or alter the server. Unless described herein, never attempt to disassemble, repair, or alter the equipment. There is a risk of an electric shock or fire as well as malfunction. Do not look into the CD-ROM drive. The CD-ROM drive uses a laser beam. Do not look or insert a mirror inside while the system is on. A laser beam is invisible; if your eyes get exposed to it, there is a risk of losing eyesight.
1-14 Before Using During Operation CAUTION Do not pull out a device during operation. Do not pull out or remove a device while it works. There is a risk of malfunction and injuries. Do not touch the equipment when it thunders. Unplug the equipment when it threatens to thunder. If it starts to thunder before you unplug the equipment, do not touch the equipment or cables. There is a risk of a fire or electric shock. Keep animals away.
Before Using 1-15 Rack-mount Model CAUTION Do not attempt to install the server yourself. To avoid a risk of injuries, users should not attempt to install the equipment into a rack. Installation should be performed by trained maintenance personnel. < For Maintenance Personnel Only > Do not remove and carry the equipment with modules mounted. When you remove this product from the rack and carry it, remove all modules that are mounted first.
1-16 Before Using Unpackaging The following section describes necessary information to use the product properly and safely. Accessories This product is shipped with various accessories. See the attached list to make sure everything is included and check the individual items. If any component is missing or damaged, contact your sales agent. Keep the accessories in a safe place. You will need them when you perform setup, addition of options, or replacement of failed components.
Chapter 2 About Operating System This chapter gives essential information on the Windows system supported by the server and how to install it.
2-2 About Operating System Installing Windows Server 2003 For installing an operating system on NEC Express5800/ft series, use NEC EXPRESSBUILDER. IMPORTANT: The NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it. The ft series setup program is exclusively used for the NEC Express5800/ft series. To execute the setup program, simply select the item [Setup] from the menu displayed when starting the system through the provided CD-ROM "NEC EXPRESSBUILDER.
About Operating System IMPORTANT: Complete all the setups such as the memory expansion and the BIOS setting before installing Windows Server 2003. NEC software package, which is to be purchased separately, is also provided with the documentation for installation. However, see this User's Guide for installation into this server. After completing the ft series setup program, make settings for failure management (e.g., memory dump (debug information) setting) according to Chapter 4.
2-4 About Operating System (This page is intentionally left blank.
Chapter 3 Installing Server This chapter describes requirements for using the product properly and safely, the setup procedures to make NEC Express5800/ft series ready for use, and how to connect peripherals.
3-2 Installing Server Installation This section describes installation of NEC Express5800/ft series. Tower Model IMPORTANT: NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it. Select a suitable site for tower model. CAUTION Observe the following precautions to use the equipment safely. There are risks of a burn, injury, or damage to physical assets. For details, see “Notes for Safe Handling” in Chapter 1. Remove all modules before moving the equipment.
Installing Server 3-3 Do not install NEC Express5800/ft series in such places as listed below. Otherwise, the server may malfunction. Place where temperatures change widely (near a heater, air conditioner, or refrigerator). Place that is subject to intense vibration. Place where corrosive gas (sodium chloride, sulfur dioxide, hydrogen sulfide, nitrogen dioxide, or ozone) is generated, or a place that is close to chemicals or exposed to chemicals. Place whose floor is covered with non-antistatic carpet.
3-4 Installing Server After fastening the main cabinet, open its front bezel to mount the CPU and PCI modules. For details, see the following section “Installation of Rack-mount Model.” Procedures are basically the same for the tower model except that its modules are mounted vertically instead of horizontally. IMPORTANT: Follow the procedures below to install the CPU and PCI modules. Note the following before installing them. Ensure the main cabinet is immobilized.
Installing Server 3-5 Installation of Rack-mount Model You can mount NEC Express5800/ft series on a rack that conforms to the EIA standards. IMPORTANT: NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it. To install a rack, contact your sales agent or maintenance personnel. CAUTION Do not attempt to install the server. To avoid the risk of personal injury, users should not attempt to install the server into the rack assembly.
3-6 Installing Server WARNING Observe the following precautions to use the server safely. There is a risk of a death or serious injury. For details, see “Notes for Safe Handling” in Chapter 1. Do not install the equipment in non-designated places. Do not connect the ground wire to a gas pipe. CAUTION Observe the following precautions to use the equipment safely. There is a risk of a burn, personal injury, or damage to physical assets. For details, see “Notes for Safe Handling” in Chapter 1.
Installing Server 3-7 Place that is close to some equipment that causes power noises (e.g., sparks caused by power-on/off using a relay). If you must install the server close to such equipment, request your sales agent for separate power cabling or noise filter installation. IMPORTANT: Temperature increase inside the rack and airflow If you install several components or the ventilation isn’t good inside the rack, the internal temperature may increase due to heat emitted from the components.
3-8 Installing Server Connection Connect peripheral devices to NEC Express5800/ft series. The server is provided with connectors for wide variety of peripheral devices on its front and rear. The figure on the next page illustrates available peripheral devices for the server in the standard configuration, and locations of the connectors for the devices. After connecting the peripheral devices, connect the provided power cords with the server, and then plug the power cords into the power outlet.
Installing Server 3-9 A rack-mount model is shown here. As for a tower model, locations of the connectors are same though the orientation of the equipment is different. IMPORTANT: Space of 1U above the main unit is needed to place the USB floppy disk drive on the main unit for a rack-mount model. For a tower model, place it on the main unit.
3-10 Installing Server After connecting cables to PCI modules, secure them with the cable ties. When completing connection to peripheral equipment, connect the two provided power cords to the server. After that, secure the cables with the cable tie provided in the server. Connect the plug at the other end of the power cord to a wall outlet with parallel double-pole grounds provided or to an uninterruptible power supply (UPS). To use the functions of the server, you should connect the server to the UPS.
Installing Server 3-11 To connect the power cords from the server to an uninterruptible power supply (UPS), use service outlets on the rear of the UPS. The UPS service outlets are categorized into two groups: SWITCH OUT and UN-SWITCH OUT. (They may be called "OUTPUT1" and "OUTPUT2".) For constant power supply, connect the power cords to a UN-SWITCH OUT outlet. (Connect the modem that is in service for 24 hours to this outlet.
3-12 Installing Server (This page is intentionally left blank.
Chapter 4 Windows Setup This chapter describes procedures for configuring boot monitoring function, setup, installing Windows, setting dual LAN configuration, setting dual disk configuration and so on.
4-2 Windows Setup ft series Setup Use NEC EXPRESSBUILDER to setup the NEC Express5800/ft series. IMPORTANT: NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it. You perform ft series setup for reinstallation. The ft series setup is the install program for the NEC Express5800/ft series. The ft series setup helps you to install Windows Server 2003. You can use the ft series setup for reinstalling Windows Server 2003 to your server as well.
Windows Setup 4-3 Setup Flow Step 1: Things Required for Setup (P.4-4) Step 2: Prepare for ft series Setup (P.4-6) Step 3: Disable Boot Monitoring Function The following flow-chart illustrates the flow of the setup procedures for the NEC Express5800/320Lc/320Lc-R server. Corresponding page numbers are shown in parentheses. (P.4-11) Step 4: Starting the ft series Setup (P.
4-4 Windows Setup Step 1: Things Required for Setup The following explains the setup procedure using the ft series setup program: IMPORTANT: Do not apply service packs to NEC Express5800/ft series based on your judgment. If you desire to apply service packs, contact your sales agent about application status and apply service packs to NEC Express5800/ft series. TIPS: For the latest information on support for Windows Service Pack, contact your sales agent.
Windows Setup 4-5 Size of the Partition to be Created The required minimum size of a partition to install the system can be obtained from the following formula: Size required for installation + paging file size + dump file size Size required for installation = 2,900MB Paging file size (recommended) = size of memory mounted* × 1.5 Dump file size = size of memory mounted* + 12MB IMPORTANT: The above paging file size is necessary for collecting debug information (memory dump).
4-6 Windows Setup Step 2: Prepare for ft series Setup Before starting ft series setup, be sure to do the following. If these preparations are not done, setup cannot be performed properly.
Windows Setup 4-7 11. When restarting process starts, remove the ROM-DOS startup disk from the floppy disk drive and power off. Initialization of hard disks is completed. Start the preparation of NEC Express5800/ft series.
4-8 Windows Setup 2-2: Prepare NEC Express5800/ft series With the power of NEC Express5800/ft series off, follow the steps below: 1. Prepare NEC Express5800/ft series. • • • • • Remove all optional PCI boards. Mount the PCI modules (for Group1/for Group2), and CPU modules (for Group1/for Group2). Insert only one hard disk to the slot1 of PCI module for Group1. Remove all LAN cables. Remove optional SCSI devices such as a tape device from the internal SCSI connector.
Windows Setup 4-9 AC inlet B (for Group1) AC inlet A (for Group2) Rear View Connect the power cords to NEC Express5800/ft series in the following order: (1) Connect the power cord to the AC inlet B (for Group1) (2) Connect the power cord to the AC inlet A (for Group2) (3) Confirm that the POWER switch of the PCI module for Group1 is illuminated.
4-10 Windows Setup (2) Make sure that the two BMC Status LEDs of the PCI modules (for Group1/for Group2) are turned off. IMPORTANT: While the BMC Status LED is red and blinking, do not perform (3) and on. Otherwise the BMC firmware may become damaged. (3) (4) (5) (6) Remove the power cord of the AC inlet A (for Group2). Check that the POWER switch of the PCI module for Group1 is turned on. Connect the power cord of the AC inlet A (for Group2).
Windows Setup 4-11 Step 3: Disable Boot Monitoring Function Check whether the power is ON and make settings for properly performing setup for later on. This equipment has a function to monitor the main unit at startup. (Enabled in the configuration at shipment) When reinstalling the operating system, this monitoring function needs to be disabled. Otherwise the installation may not be done properly. Follow the steps in this section and make proper settings.
4-12 Windows Setup 3. Confirm that the BMC Status LED ( ) on both PCI modules are off and press the illuminated POWER switch which is located on the front panel. BMC Status LED PCI modules CPU modules POWER switches* * Only the lit POWER switch can be used. IMPORTANT: Do not turn off the power before the "NEC" logo appears. When powering on, make sure that the BMC Status LED ( PCI modules are off and then press the power switch. ) on the both After a while, the "NEC" logo will appear on the screen.
Windows Setup 4-13 4. When the message “Press to enter SETUP” or “Press to enter SETUP or Press to Network” on the display screen, press F2. The BIOS Setup Utility “SETUP” starts and the Main menu is displayed on the screen. 5. Move the cursor onto "Advanced" and select “Advanced”. The Advanced menu will be displayed.
4-14 Windows Setup 6. Move the cursor onto “Monitoring Configuration” and press Enter. The Monitoring Configuration submenu appears. 7. Move the cursor onto “Boot Monitoring” and press Enter. Parameters will be displayed. 8. Among the parameters, choose “Disabled” and press Enter. The current display of the configuration for Boot Monitoring will be changed to “Disabled”.
Windows Setup 4-15 9. 10. Move the cursor onto "Exit" to display the Exit menu. Move the cursor onto “Save Changes & Exit” and press Enter. The confirmation window will appear. 11. Select “Yes” and press Enter. After the configuration data is saved and SETUP is terminated, the system is rebooted. This is the end of steps for switching boot monitoring function. TIPS: When reinstalling the OS, power off this equipment to prepare for reinstallation.
4-16 Windows Setup Step 4: Start the ft series Setup Follow the steps below to perform ft series setup: IMPORTANT: If you skip the settings of Step 3 “Disable Boot Monitoring Function” (page 4-11), BIOS will be restarted forcefully while Windows setup screen is shown and the setup will be unsuccessful; BIOS may repeat Windows setup in an invalid manner. In such case, you will need to restart the setup procedures from the beginning. 1. Turn on the NEC Express5800/ft series.
Windows Setup 4-17 6. “Important 1” message will appear. Read the message and follow the instructions. *** Important Notice 1 - No optional boards should be installed in the PCI modules at this time. If there are optional boards installed in the PCI modules, please abort the installation process, power down the system and remove the optional boards. Afterwards power on the system and restart the intallation process.
4-18 Windows Setup 9. Important 4” message will appear. Read the message and follow the instructions. *** Important Notice 4 - All PCI and CPU modules should be inserted into the server. If there are any removed PCI or CPU modules, please insert them at this time and press any key to continue the installation process. Strike a key when ready . . . 10. “Important 5” message will appear. Read the message and follow the instructions.
Windows Setup 4-19 CHECK: The message “The system will be rebooted.” appears on the screen momentarily. The server will restart automatically and no user intervention is required. Installing required software ... Formatting drive... FORMAT v7.10 (Revision4.11.1364) Copyright(c) 1989-2002 Datalight, Inc. Formatting 3.07G XX percent complete. After the hard disk drive is formatted, the message about copying the NEC Express5800/ft series system software to the system drive from the CD-ROM.
4-20 Windows Setup CD-ROM and NEC EXPRESSBUILDER will be started. 13. After the system is restarted, the following message will appear: If you have an additional ft Update CD and wish to use it, insert the CD-ROM into the CD-ROM drive. Use an additional ft Update CD [Y,N]? If you have “NEC Express5800/ft series ft Update CD” handy, enter “Y”. If you do not have “NEC Express5800/ft series ft Update CD” handy and perform installation using “NEC EXPRESSBUILDER” only, enter “N”. 14.
Windows Setup 4-21 IMPORTANT: When the usage of the “NEC Express5800/ft series ft Update CD” is not selected, the above message will not appear. Go on to 17. 17. A message prompting you for what language version of Windows Server 2003 to install will appear. Which language version of Windows Server 2003 is to be installed? E (English), F (French), G (German), I (Italian), or S (Spanish)? [E,F,G,I,S]? 18.
4-22 Windows Setup Enter the size of the partition to create. Note 1:The minimum partition size is 3072 MByte. 1GByte is 1024MByte. Note 2:If a size larger the HDD capacity is specified, the entire capacity of the HDD will be used. Note 3:Input "ALL" to use the entire capacity of the HDD for the system partition. Desired Size (Unit: MByte) 22. The confirmation message for input size of the partition to install the OS will appear. When it is correct, enter “Y”. If it is wrong, enter “N” and press Enter.
Windows Setup 4-23 26. When the completion of copying Microsoft HotFix, the following message will appear. Follow the instruction on the screen, insert appropriate CD-ROM and press any key. Microsoft HotFix will be copied to the Hard Disk. - If you are using only the NEC EXPRESSBUILDER for ft series setup, insert the NEC EXPRESSBUILDER to the CD-ROM drive, and press any key to continue the installation process. .
4-24 Windows Setup 29. When copying is complete, the installation of Windows Server 2003 will be started automatically. Windows Setup Please wait while Setup copies files to your hard disk. Setup is copying files… 50% Copying:XXXXXXXX IMPORTANT: During the automatic installation process (from 28 to 38) a window may be displayed showing the progress as well as application installation wizards. No user intervention is required until the “Windows Setup Wizard” in 39 is displayed.
Windows Setup 4-25 31. After the the system is automatically rebooted, the file system will be changed from FAT32 to NTFS and the file system will be converted automatically. There is no user intervention. 32. After the system is restarted, the setup screen will be displayed and the setup will proceed automatically. There is no user intervention.
4-26 Windows Setup 35. After restarting, the following screen will appear and the installation will be continued. User intervention is not required. The NEC Express5800/ft series software is installed automatically. NEC Express5800/ft series clear installation ** Please do not perform any operations. ** ** The system will restart automatically.
Windows Setup 4-27 37. The following screen will appear and the setup of Express Report Service will start. User intervention is not required. The Express Report Service Setup wizard starts and installation is done automatically. 38. The following screen will appear and installation of Windows HotFix will begin. The Windows HotFix install wizard starts up and installation is done automatically. User intervention is not required.
4-28 Windows Setup 39. After installation of Windows HotFix is complete, installation is continued. User intervention is not required. When the NEC Express5800/ft series software is installed, the NEC Express5800/ft series will be restarted automatically. NEC Express5800/ft series clear installation ** Please do not perform any operations. ** ** The system will restart automatically.
Windows Setup 4-29 40. After restarting, the [Welcome to the Windows Setup Wizard] screen will appear. Click [Next>] and follow the instruction of the wizard. After completing operations in the wizard, the NEC Express5800/ft series will be restarted automatically. IMPORTANT: Read [License Agreement] thoroughly. If you agree, click [I accept this agreement.] and click [Next>]. If you do not agree, click [I don’t accept this agreement.] and click [Next>].
4-30 Windows Setup 43. The following screen will appear. Follow the instruction in the screen and remove the CD from the drive, and then press any key. The NEC Express5800/ft series restarts automatically. Insert NEC EXPRESSBUILDER CD-ROM into the CD-ROM drive. Strike a key when ready . . .
Windows Setup 4-31 Step 5: Set Dual LAN Configuration The NEC Express5800/ft series builds a dual LAN configuration by using "Stratus emb-82559 10/100 Enet Adapter" (100Base) and "Stratus emb-82544GC Copper Gigabit Adapter" (1000Base) mounted as standard on the PCI module. If an Ethernet adapter is not used (not connected to cable), set it to “Disable” in [Network Connections] from Control Panel.
4-32 Windows Setup [Team #1: Adaptive Fault Tolerance Mode] is added to Network Component Tree. 4. Select [Stratus emb-82559 10/100 Enet Adapter] from Network Component Tree. The pop-up menu appears. Select [Team #1: Adaptive Fault Tolerance Mode] from [Add to Team], and add the adapters. You will see the warning message when you add the team. You can ignore this warning message by clicking [OK]. This warning message is to inform you that only one adapter is added to the team. 5.
Windows Setup 4-33 7. Click [OK]. The [Intel(R)PROSet II] dialog box closes after a while, and the settings become effective. IMPORTANT: The [Digital signature not found] dialog box may appear (several times). If it appears, click [Yes]. After setting dual configuration, “Intel(R) Advanced Network Services Virtual Adapter” will appear on the [Network and dialup connection] or the [Device Manager] dialog box.
4-34 Windows Setup Step 6: Set Dual Disk Configuration NEC Express5800/ft series secures data by setting dual disk configuration using “Disk Management” or “RDR (Rapid Disk Resync) function”. Be sure to make dual disk settings by referring to the procedure. For models which do not support the RDR (Rapid Disk Resync) function: → Go to “Setting Dual Disk Configuration by Disk Management” (page 4-34).
Windows Setup 4-35 4. Confirm that the hard disk to be converted is the hard disk where the system is installed and click [Convert]. If the selected hard disk contains a system partition, you will have to restart the computer to complete the upgrade of the hard disk. The message also states that file systems on any of the hard disks to be upgraded will be forcedly dismounted. This means if any file systems are in use at the time of upgrade, they will be dismounted, so that the upgrade can continue. 5.
4-36 Windows Setup 6. If the inserted hard disk is not a dynamic disk, right-click the disk and perform “Convert to Dynamic Disk”. 7. Right-click the dynamic disk volume for creating mirror and click [Add Mirror…]. 8. Select the newly inserted HDD in the window which appears, and click [Add Mirror] to continue with the mirroring process. IMPORTANT: When you click [Add Mirror…], the [Logical Disk Manager] dialog box will appear, but this is not an error. Click [OK].
Windows Setup 4-37 9. 10. Confirm that the mirroring of the HDD has been started in the disk manager. When the “Resynching” shown in 9 changes to “Healthy”, disk mirroring has completed. Continue the operation by following the instructions on the screen.
4-38 Windows Setup Setting Dual Disk Configuration by the RDR (Rapid Disk Resync) function On a model supporting the RDR function, dual disk configuration is set for each pair of disks by the RDR function of the ft control software. By setting RDR, duplication is configured with disks in the corresponding slots as shown below, and each pair of disks is recognized as one virtual disk from Windows (the disk manager or the device manager, etc.).
Windows Setup 4-39 Registering RDR key When using the RDR function for the first time, follow the steps below to register the key: 1. Insert “RDR Key FD” that came with the server into the floppy disk drive. 2. From [Start], select [All Programs] – [Accessories] – [Windows Explorer] to start Windows Explorer, and then double-click “RDRreg.bat” in FD. 3. The message “RDR registration has completed.” appears on the command prompt, and the RDR function becomes available. 4.
4-40 Windows Setup 3. When RDR is successfully configured, the following two pop-up messages appear. On the “Warning” pop-up, click [OK], and on the “System Restart Warning” pop-up, click [Yes]. IMPORTANT: Clicking [Yes] on the “System Restart Warning” pop-up will restart the system in 2 minutes. If the pop-up appears multiple times, follow the instruction to restart the system. 4. The following pop-up appears, and the system will be restarted in two minutes: 5.
Windows Setup 4-41 6. Start “RDR Utility”, right-click the mounted disk and click [Add RDR Virtual Disk]. IMPORTANT: If the mounted disk has not been initialized on Windows, RDR will be configured and synchronization will be performed automatically. Therefore this operation is not required. Go to 7 and check the duplication status.
4-42 Windows Setup 7. Select [Logical Disk Information] then [RDR Virtual Disk] and confirm that the duplication process has been started. TIPS: It takes about 16 minutes to set dual disk configuration for an 18GB disk. IMPORTANT: Depending on the progress of duplication, the value changes to 0 percent, 25 percent, 50 percent, then 75 percent.
Windows Setup 4-43 Step 7: Update Software Follow the instructions below and apply necessary update modules: Apply “ft control software Ver3.0 Update module No.001 FD.” Procedure for applying “ft control software Ver3.0 Update module No.001 FD” 1. Insert “ft control software Ver3.0 Update module No.001 FD” which was shipped with the server into the floppy disk drive. 2.
4-44 Windows Setup (After modification) [boot loader] timeout=30 default=multi(0)disk(0)rdisk(0)partition(1)\WINNT [operating systems] multi(0)disk(0)rdisk(0)partition(1)\WINNT="Windows Server 2003, Enterprise" /fastdetect /PAE Step 9: Create Volume With NEC Express5800/ft series, all volumes needs to be mirrored.
Windows Setup 4-45 Step 10: Set Network for NEC ESMPRO Agent NEC ESMPRO Agent is required for continuous operation, and it is automatically installed by “ft series setup”. To operate NEC ESMPRO Agent, you need to make setting the SNMP. To change the settings of the SNMP Service: 1. Double-click [Administrative Tools] in [Control Panel]. 2. Start [Services] in [Administrative Tools]. 3. Select [SNMP Service] from the service list and then [Properties] in the [Action] menu.
4-46 Windows Setup < Setup of receiving SNMP packets from specific communities only > Change the name of the community receiving SNMP packets from the default “public” to any name. IMPORTANT: If the community name is changed, the community of NEC ESMPRO Agent is changed and registered by starting from [Control Panel]. To change the community to another and register it, use the [SNMP Community] list box in the [General] tab.
Windows Setup 4-47 Step 11: Enable Boot Monitoring Function Enable the “Boot Monitoring” setting which has been disabled in “Step 3: Disable Boot Monitoring Function” (page 4-11). See “Step 3: Disable Boot Monitoring Function” (page 4-11) and change the setting to “Enabled”.
4-48 Windows Setup Step 12: Set up Failure Management Make the following settings beforehand to ensure quick recovery from failure. Set Memory Dump (Debug Information) This section explains the setting for collecting memory dump (debug information) in the server. IMPORTANT: Notes on memory dump The maintenance personnel designated by your sales agent are responsible for collecting memory dump. Customers should make settings of memory dump only.
Error! Style not defined. 4-49 4. Enter the location, where debug information is to be written, in the text box. When writing debug information under the file name "MEMORY.DMP" in the D drive: D:\MEMORY.DMP This server has the following location as a default value for installation. It is recommendable to store file in this default location. %SystemDrive%\NECDump\MEMORY.DMP IMPORTANT: [Complete memory dump] should be specified for writing debug information.
4-50 Windows Setup 5. Click [Settings] in the [Performance] box. The [Performance Options] window appears. 6. Click the [Advanced] tab on the [Performance Options] window. 7. Click [Change] in the [Virtual memory] box.
Error! Style not defined. 4-51 8. Change the value set for [Initial Size] in the [Paging file size for selected drive] box to the [Recommended] value or more, and then click [Set]. IMPORTANT: Be sure to create the file in the size more than [Recommended] value in the OS partition. If a value smaller than the [Recommended] value is set for [Initial Size] of the paging file, accurate debug information (memory dump) may not be collected.
4-52 Windows Setup Set Dr. Watson Dr. Watson of Windows Server 2003 is a debugger for application errors. When detecting an application error, Dr. Watson diagnoses the NEC Express5800/ft series, and records the diagnostic information (log). Take the following steps to collect diagnostic information: 1. Click [Run...] from [Start]. 2. Enter "drwtsn32.exe" in the [Open] box, and click [OK]. The [Dr. Watson for Windows] dialog box appears. 3.
Error! Style not defined. 4-53 5. Select the following check boxes in the [Options] box. [Dump Symbol Table] [Dump All Thread Contexts] [Append To Existing Log File] [Create Crash Dump File] For the above functions, see the online help. 6. Click [OK].
4-54 Windows Setup Install a Network Monitor A network monitor is useful for examining the causes of network failures and taking the countermeasures. To use the network monitor, you need to restart the system after the installation. It is recommended to install the network monitor before a failure occurs. 1. From the [Start] menu, select [Control Panel]. The [Control Panel] dialog box appears. Click the [Add/Remove Programs] icon. The [Add/Remove Programs] dialog box appears. 2.
Error! Style not defined. 4-55 Set MTBF Type In this section, you can specify operations to be performed when failures occur on CPU or PCI modules. NEC Express5800/ft series manages the MTBF (mean time between failure) of hardware components. If a fault occurs on a CPU or PCI module, the NEC Express5800/ft series calculates the MTBF again. If the calculated value is lower than the pre-defined threshold, the NEC Express5800/ft series disables the applicable module.
4-56 Windows Setup
Error! Style not defined. 4-57 Step 13: Back up System Information After setting up the system, back up the system information using the Off-line Maintenance Utility. Without backup for system information, the information and settings that are specific to your server cannot be restored if the server is repaired. Take the following steps to make a backup copy of the system information: 1. Get a 3.5-inch floppy disk. 2.
4-58 Windows Setup (This page is intentionally left blank.
Chapter 5 Procedures after Completion of Installation This chapter describes how you install management utilities, how you back up system information, and setup of PCs on the network. You may need to confirm these procedures while the system is running.
5-2 Procedures after Completion of Installation Installing Management Utilities The provided "NEC EXPRESSBUILDER" CD-ROM contains "NEC ESMPRO Agent" for monitoring NEC Express5800/ft series and "NEC ESMPRO Manager" for managing the NEC Express5800/ft series. It also contains NEC ExpressCluster SRE for application fault tolerance, please see the ExpressCluster SRE Installation and Configuration Guide for setup instructions.
Procedures after Completion of Installation 5-3 Operation Environment NEC ESMPRO Agent can be operated in the hardware and software environments shown below. Hardware • • • Installation system Memory Empty capacity of hard disk Software NEC Express5800/ft series Memory capacity required to operate OS + 25.0 MB or larger 50.0 MB or larger Windows Server 2003, Windows 2000 Preparation before Setup Be sure to read the following description before system installation or setup.
5-4 Procedures after Completion of Installation 4. Enter “public” in the [Community name] box in the [Traps] property sheet and click the [Add to list] button. IMPORTANT: To change the community name of traps to be received from the default “*” in the NEC ESMPRO Manager site, enter the same name as the community name newly set in the NEC ESMPRO Manager site. To receive trap from NEC ESMPRO Agent at the NEC ESMPRO Manager machine, both community names should be the same. 5. Click the [Add...
Procedures after Completion of Installation 5-5 IMPORTANT: If the community name is changed, the community of NEC ESMPRO Agent is changed and registered by starting from [Control Panel]. To change the community to another and register it, use the [SNMP Community] list box in the [General] tab. To allow NEC ESMPRO Agent to receive SNMP packets sent from NEC ESMPRO Manager, set the send community name in NEC ESMPRO Manager to be the same as that accepted by the SNMP Service in NEC ESMPRO Agent. 7.
5-6 Procedures after Completion of Installation Installation NEC ESMPRO Agent is automatically installed together with the installation or re-installation of the NEC Express5800/ft series. NEC ESMPRO Agent may be installed manually on the master control menu of NEC EXPRESSBUILDER as follows: 1. Login to the system with user name “Administrator.” 2. Insert CD-ROM "NEC EXPRESSBUILDER" into the CD-ROM drive.
Procedures after Completion of Installation 5-7 4. Click [Agent] in the main menu of the NEC ESMPRO setup. TIPS: The available menus vary depending on OS types. (The menus that cannot be installed are displayed gray.) IMPORTANT: Double-clicking to select a menu may display two same dialog boxes. Click the [End] button to close one of the dialog boxes. If you click the [Cancel] button during setup, the message asking whether to stop or not to stop the installation will appear.
5-8 Procedures after Completion of Installation 7. Enter the path in which NEC ESMPRO Agent is installed and click the [Next] button. The NEC ESMPRO Agent module is installed below the \ESM directory of the root partition in default. If no problem is found, click the [Next] button without any modification. To change the installation directory, click the [Reference] button, specify the desired installation directory with the full path including the drive name, and click the [Next] button. 8.
Procedures after Completion of Installation 5-9 Setup of NEC ESMPRO Agent The settings of installed NEC ESMPRO Agent remain unchanged from those at shipment. Click the [Start] button, [Setting], and [Control Panel] sequentially to open [Control Panel]. If you double-click the [NEC ESMPRO Agent] icon in [Control Panel], the property dialog box will appear. Modify the setting of each sheet in the dialog box to be fit to the used environment.
5-10 Procedures after Completion of Installation Uninstall The configuration of NEC ESMPRO Agent and BMC and the uninstallation of BMC FW Update Service are described below. Uninstallation of NEC ESMPRO Agent The procedure of uninstalling NEC ESMPRO Agent is described below. IMPORTANT: Uninstallation of NEC ESMPRO Agent Start the uninstallation of NEC ESMPRO Agent after the system is started completely.
Procedures after Completion of Installation 5-11 Uninstallation of BMC Configuration and BMC FW Update Service If NEC ESMPRO Agent is installed, the uninstaller of the BMC configuration and that of NEC BMC FW Update Service are registered. The use of these uninstallers allows the BMC configuration and NEC BMC FW Update Service to be deleted as follows: 1. Start [Add/Remove Programs] on [Control Panel]. 2. Select [NEC BMC Configuration] or [NEC BMC FW Update Service] and click [Change/Remove].
5-12 Procedures after Completion of Installation NEC ESMPRO Manager Linked with NEC ESMPRO Agent installed in the server, NEC ESMPRO Manager monitors the server status and receives alerts from the server. NEC ESMPRO Agent Error Notify NEC ESMPRO Manager Monitor When a failing module in the server is to be replaced, NEC ESMPRO Manager enables logical module disconnection from the server and logical installation after module replacement.
Procedures after Completion of Installation 5-13 System Requirement The hardware and software environment in which NEC MWA runs is: • Management PC (to install NEC MWA) NEC MWA runs on a computer where Windows is operated. For more information, see “MWA First Step Guide.” • The servers that can be maintained remotely by NEC MWA Servers which the User’s Guide provided with NEC Express5800/ft series include descriptions of NEC MWA. The servers are equipped with RomPilot or BMC.
5-14 Procedures after Completion of Installation Setting up PCs on a Network If you have computers running on Windows Server 2003, Windows XP/2000/NT4.0, Windows 95/98 that communicate with NEC Express5800/ft series using the TCP/IP protocol, make the following settings on all computers. 1. Copy the following in the NEC EXPRESSBUILDER CD-ROM or ft control software, UPDATE CD-ROM to any directory. \STRATUS\LANG\EN\PROG\FTREG.EXE TIPS: ft Update CD is for updating ft control software.
Procedures after Completion of Installation 5-15 Type: REG_DWORD Set value: 5 Windows 95/98/Me: Registry key: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\VxD\MSTCP Values: MaxConnectRetries Type: String Set value: 5 Values: MaxDataRetries Type: String Set value: 8
5-16 Procedures after Completion of Installation Confirmation of the ft Control Software Version The following describes how to check the version of ft control software, which consists of various types of software for fault tolerance. Perform the procedure when you need to check the ft control software version of the current system before adding units or attachment to NEC Express5800/ft series. A tool for checking the version is provided. Confirm the version following the steps below: 1.
Procedures after Completion of Installation 5-17 Notes to apply the Windows Service Pack Customers should not apply service pack on NEC Express5800/ft series by themselves. IMPORTANT: If you want to apply service pack, contact your sales agent about the application status and apply service pack on NEC Express5800/ft series.
Chapter 6 Troubleshooting This chapter describes what to do when files needed to operate the OS are damaged and any trouble occurs on the product.
6-2 Troubleshooting System Repair If the system cannot be operated by some reason, use Recovery Console to restore the system. However, this method is only recommended to users or administrators who have good knowledge of the system. When you have restored a damaged file by using Recovery Console, always update the system as described later in this chapter. IMPORTANT: If hard disks cannot be recognized, the system cannot be repaired.
Troubleshooting 6-3 If you have a computer that runs Windows Server 2003, Windows 2000/XP/NT or Windows 95/98/Me. You can also create a “Windows Server 2003 OEM-DISK for NEC EXPRESSBUILDER” by the steps below: 1. Prepare a 3.5-inch floppy disk. 2. Insert the NEC EXPRESSBUILDER CD-ROM into the drive of a computer that runs Windows Server 2003, Windows 2000/XP/NT or Windows 95/98/Me. 3. From [Setup], select [Make OEM-Disk]. 4. Follow the instructions on the screen to insert the floppy disk.
6-4 Troubleshooting Starting up Recovery Console You can start up Recovery Console in two ways: Start up Recovery Console installed on the system. Start up Recovery Console from the Windows Server 2003 CD-ROM. Installing Recovery Console on the system 1. Start up the NEC Express5800/ft series and log on to Windows Server 2003. 2. Insert the Windows Server 2003 CD-ROM into the drive. 3. From [Start] of the taskbar, select [Run...] to run. CD-ROM drive:\i386\winnt32.
Troubleshooting 6-5 (a) Insert the Windows Server 2003 CD-ROM into the drive. (b) When the CD is set, reset the system (press Ctrl + Alt + Delete) or press the power switch to power off and on to reboot the NEC Express5800/ft series. (c) When the following message appears, press any key to start up from the CD-ROM. IMPORTANT: Press any key while the message is displayed.
6-6 Troubleshooting (b) Insert the “Windows Server 2003 OEM-DISK for NEC EXPRESSBUILDER” into the floppy disk drive, and then press Enter. (c) Specify HAL in the floppy disk, and press Enter. 4. When the screen to select SCSI drivers appears, follow the steps below. (a) Press the S key.
Troubleshooting 6-7 (b) Insert the “Windows Server 2003 OEM-DISK for NEC EXPRESSBUILDER” into the floppy disk drive, and then press Enter. (c) Select all SCSI drivers in the floppy disk and then press Enter. IMPORTANT: There are more than one SCSI drivers in “Windows Server 2003 OEM-DISK for NEC EXPRESSBUILDER”. Repeat procedures from (a) to (c) in the step 4 to select all SCSI drivers in the floppy disk shown on the screen.
6-8 Troubleshooting 5. When you start up Recovery Console from Windows Server 2003 CD-ROM, the following message appears. Press the R key to boot Recovery Console. Welcome to Setup. This portion of the Setup program prepares Microsoft(R) Windows(R) to run on your computer. - To set up Windows now, press ENTER. - To repair a Windows installation using Recovery Console, press R. - To quit Setup without installing Windows, press F3.
Troubleshooting 6-9 Updating the System IMPORTANT: NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to update the system. You will need to update the system after you repair the system using Recovery Console. IMPORTANT: Make sure to follow the steps below when you have restored the system by using Recovery Console. Check the configuration for boot monitoring function.
6-10 Troubleshooting - Status emb-82559 10/100 Enet Adapter - Status emb-82544GC Copper Gigabit Adapter - Status AA-U51500 10/100 Enet Adapter (100BASE-TX) - Status AA-U57000 Fiber Gigabit Adapter (1000 BASE-SX) - NEC 8490 XT Copper Gigabit Adapter (1000 BASE-T) You will then see the dialog box on the right of this paragraph. This is because one of two teamed adapters constituting dual configuration is removed. Click [Yes], to remove the adapter from Team.
Troubleshooting 6-11 At that time, the dialog box shown on the right is displayed. This is a message for confirmation, so click the [Yes] button. Remove all teams displayed on the [Intel PROSet II] dialog box in the same manner. 5) Click the [OK] button on the [Intel PROSet II] dialog box, close it, and make a setup effective. The dual LAN will be canceled. 3. Uninstall Intel(R) PROSet II. IMPORTANT: Intel(R) PROSet II will be reinstalled at system’s update (described at section 5).
6-12 Troubleshooting 3) Select [Intel(R) PROSet II] from a list of [Currently installed programs:]. 4) Click [Change/Remove]. At that time, the message on the dialog box will be displayed. This is a message for confirmation of deletion, so click [OK]. 5) Close the [Add or Remove Programs] dialog box. 6) Reboot the system. IMPORTANT: Be sure to reboot before updating the system. If you perform the next procedure (installation of PROSet II) without rebooting, PROSet II does not start after reboot.
Troubleshooting 6-13 4. After rebooting the system, log on to the system as a user with Administrative account. IMPORTANT: Check the dual system is configured properly. (Check that STATUS LED 2 of each PCI module stays green.) 5. Follow the steps below to update the system: IMPORTANT: Uninstalled Intel(R) PROSet II at section 3 will be reinstalled at system’s update. Do not input or output data during the update process.
6-14 Troubleshooting (Conditions) (Remedies) 7. The dialog appears when the drive, whose available space is the biggest in the NTFS volumes recognized by the system (includes network connection) (*1), fulfills either condition below: - Security limitation of READ_ONLY is set. - There is no sufficient space on the drive. (*1) The drive is where temporary files for applying HotFix are expanded by default. Make sure to perform the following steps on the [Choose Directory For Extracted Files] dialog box.
Troubleshooting 6-15 4) of machine. (See page 4-9 for details.) - If PCI module (for Group2)’s POWER switch is lit green, unplug the power cord connected to “AC inlet A (for Group 2)” on the rear of machine. (See page 4-9 for details.) Check that the POWER switch of the other PCI module is lit green. If it is not lit green, do the procedures from b) again. 5) Plug the power cord which was unplugged in c) again.
6-16 Troubleshooting 9. Start Device Manager, choose [View] then [Device by connection] and do the following: a) Delete the red-circled device entries in the following figure. IMPORTANT: Do not uninstall entries for “Stratus Fault Tolerant 69000 Video” which appears as child entries of “ACPI Multiprocessor ftServer”. Delete the following device entries: - StratusDual Initiated Disk Device - StratusDual Initiated Disk Device - Stratus Fault Tolerant 69000 Video - ! Unknown Device a-1.
Troubleshooting 6-17 a-5. The message of update completion will be displayed. "[Update of the driver Completion] Press any key and terminate." b) When N8803-031F (Fibre Channel Controller) is connected b-1. Start up [Device Manager] by selecting [Start] - [All Programs] - [Administrative Tools] - [Computer Management]. Check to see [Qlogic QLA23xx PCI Fibre Channel Adapter] appears under [SCSI and RAID Controllers].
6-18 Troubleshooting d-3. d-4. d-5. Run the following command from Command Prompt and move to the folder with the batch file. CD-ROM drive:\> cd \WINNT\DOTNET\EN Run the following command from Command Prompt for updating the driver. CD-ROM drive:\WINNT\ DOTNET\EN > N8104103.BAT The message of update completion will be displayed. "[Update of the driver Completion] Press any key and terminate.
Troubleshooting 6-19 Note: If you restart the system without deleting the disconnected option boards, the following dialog box may appear at startup: “At least one service or driver failed during system startup. Use Event Viewer to examine the event log for details.” 11. Reboot the system. 12. After the system has rebooted, log on as a user with Administrative account. IMPORTANT: Check that the dual system is configured properly.
6-20 Troubleshooting Troubleshooting This section describes what you should do when a trouble occurs in the product. Problems with NEC EXPRESSBUILDER When the server is not booted from the NEC EXPRESSBUILDER CD-ROM, check the following: Did you set the NEC EXPRESSBUILDER CD-ROM during POST and restart the server? → If you do not set the NEC EXPRESSBUILDER CD-ROM during POST and restart the server, an error message will appear or the OS will boot.
Troubleshooting 6-21 Problems with Windows Setup The following message is displayed when the setup starts. The specified disk is not found. Terminating SW installation. → The disk to install the system is not connected properly. Check if the hardware is properly installed and connected. The following message is displayed while copying files from CD-ROM. xxxxx : Not Ready xxxxxxxxxxxxxxxxxxZ xxxxx(A), xxxxx(R), xxxxx(F) → Press R. If this message still appears, perform the setup again.
6-22 Troubleshooting “Display Settings” is displayed on lower right of the screen. → Select [Display Properties] – [Settings] tab – [Color Quality]. And then change the “Colors” setting to “Medium (16 bit)”or higher. During a setup, “Previous Operating System C:” was selected on a selection screen of the operating system. → The process will be stopped along the display of DOS prompt or black screen. In this case, press Ctrl + Alt + Delete, or turn off the power to reboot the system.
Troubleshooting 6-23 Problems with NEC ESMPRO Setup A menu which cannot be chosen with a setup main menu. → The available menus vary depending on the OS types. (The menus that cannot be installed are displayed in gray.) Stop the setup of NEC ESMPRO Agent on the way. → If you click [Cancel] during the setup, the message asking whether to stop or not to stop the installation will appear. You can stop the installation by clicking [Stop] (the main menu remains displayed).
6-24 Troubleshooting Problems with System Repair Cannot create the “Windows Server 2003 OEM-DISK for NEC EXPRESSBUILDER” with “NEC Express5800/ft series Update CD”. Is the command properly specified? → Make sure to specify the LANGENG since it is an argument. “Windows Server 2003 OEM-DISK for NEC EXPRESSBUILDER” will not be created if LANGENG is not specified as an argument. For details, see ‘If you have an update CD-ROM “NEC Express5800/ft series ft Update CD (Ver:n.
Troubleshooting 6-25 PROSet II does not start after the system is updated. Did you reboot the system after breaking dual LAN configuration and uninstalling PROSet II? → PROSet II does not start if the system’s update was performed without rebooting after breaking dual LAN configuration and uninstalling PROSet II. Also, system performance may become unstable. In such case, install PROSet II again by following the steps below: 1) Start a command prompt.
6-26 Troubleshooting N8800-063F/064F NEC Express5800/320Lc/320Lc-R User's Guide (Setup) 1st Edition 12-2004 856-124610-001- A