ND-45504 (E) CHAPTER 4
Page 73
Revision 2.0
PN-24DTA (DTI)
(3) Switch Settings
Switch Settings
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
SENS
(Rotary SW)
Note 1
4 - F Set the switch to match the AP Number (04 - 15) to be set by CM05.
0 - 3 Not used
MB (Toggle SW)
Note 2
UP
For make-busy
For normal operation
SW
(Piano Key SW)
1
ON
Clock signal from a master office is sent to the PLO 0 in-
put on the MP card.
OFF
Clock signal from a master office is not sent to the PLO
0 input on the MP card.
2
ON
Clock signal from a master office is sent to the PLO 1 in-
put on the MP card.
OFF
Clock signal from a master office is not sent to the PLO
1 input on the MP card.
3
ON Remote loop-back
For normal operation
4
ON Local loop-back (AIS send)
For normal operation
5
Set the equalizer according to the cable length
between the PBX and the MDF.
OFF
6
OFF
7
OFF
8 Always set to OFF
AP NO.
SW NO.
1004 05 06 07 08 09 11 12 13 14 15
456789ABCDEF
ON
DOWN
ON
OFF
4
3
2
1
5
6
7
8
OFF
OFF
ON
OFF
80 - 120 m (262.5 - 394 ft.)
SW-5 SW-6 SW-7 CABLE LENGTH
ON ON
0 - 40 m ( 0 - 131.2 ft.)
40 - 80 m (131.2 - 262.5 ft.)
120 - 160 m (394 - 525 ft.)
160 - 200 m (525 - 656 ft.)
Signal is not sent
ONON ON
ONON OFF
OFFON OFF
ONOFF ON
OFFOFF OFF
ON
ON
OFF