user manual

ND-45504 (E) CHAPTER 4
Addendum-001 Page 71
JULY, 1998 Revision 2.1
PN-CK00 (PLO)
Note 1:
When the power is on, flip the MB switch ON (UP position) before plugging/unplugging the circuit card.
Note 2: When using this card, set the SW2 switch on the PN-CP00/PN-CP00-B/PN-CP03 (MP) as follows.
SW2-2: OFF
SW2-3: ON
Note 3: When using this card for providing a master office clock signal, set the SW0 switch on the PN-CK00 and
the SW switch on the PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A mounted in PIM0 as fol-
lows.
PN-CK00 card PN-24DTA/PN-24DTA-A card PN-30DTC/PN-30DTC-A card
SW0-1: OFF SW-1: OFF SW-1: OFF
SW0-2: OFF SW-2: OFF SW-2: OFF
SW0-3: OFF
SW0-4: OFF
SW0-8: ON
Note 4: When using this card as a sub-master, set the SW0 switch on the PN-CK00 and the SW switch on the
PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A as follows:
For 1.5MHz interface:
PN-CK00 card PN-24DTA/PN-24DTA-A card
SW0-1: OFF SW-1: ON
SW0-2: ON SW-2: OFF
SW0-3: OFF
SW0-4: ON*
SW0-8: ON
* Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI
card is mounted in PIM0.
For 2MHz interface:
PN-CK00 card PN-30DTC/PN-30DTC-A card
SW0-1: ON SW-1: ON
SW0-2: ON SW-2: OFF
SW0-3: ON
SW0-4: ON*
SW0-8: ON
* Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI
card is mounted in PIM0.