user manual
ND-45504 (E) CHAPTER 4
Addendum-001 Page 68-3
JULY, 1998 Revision 2.1
PN-CC01 (ETHER)
3. Switch Settings
Note 1: When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the Circuit card.
Note 2: Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more
than one PBX is installed in the same network, assign the lower 4 digits of the following MAC address by
SW1 and SW2 to prevent duplicate addresses.
Switch Settings
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
MB (Toggle SW)
Note 1
UP For make-busy
For normal operation
SW1 (Dip SW)
Note 2
1 (D15) ON
2 (D14) ON
3 (D13) ON
4 (D12) OFF
5 (D11) ON
OFF
6 (D10) ON
OFF
7 (D9) ON
OFF
8 (D8) ON
OFF
SW2 (Dip SW)
Note 2
1 (D7) ON
OFF
2 (D6) ON
OFF
3 (D5) ON
OFF
4 (D4) ON
OFF
5 (D3) ON
OFF
6 (D2) ON
OFF
7 (D1) ON
OFF
8 (D0) ON
OFF
00004CA4 XX XX (HEX)
According to the switch setting of SW2 (D7-D0)
According to the switch setting of SW1 (D15-D8)
Fixed
ON
DOWN
1 2 3 4 5 6 7 8
ON
MAC ADDRESS SWITCH SETTING
00004CA4 X X X X
(HEX)
Fixed
SW1-1 (D15)
SW1-2 (D14)
SW1-3 (D13)
SW1-4 (D12)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
SW1-5 (D11)
SW1-6 (D10)
SW1-7 (D9)
SW1-8 (D8)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
SW2-1 (D7)
SW2-2 (D6)
SW2-3 (D5)
SW2-4 (D4)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
SW2-5 (D3)
SW2-6 (D2)
SW2-7 (D1)
SW2-8 (D0)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON: 0 OFF: 1
1 2 3 4 5 6 7 8
ON