user manual

CHAPTER 4 ND-45504 (E)
Page 60
Revision 2.0
PN-AP01 (AP01)
(3) Switch Settings
Switch Settings
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
SENSE
(Rotary SW)
Note 1
4 - F Set the switch to match the AP Number (04 - 15) to be set by
CM05.
0 - 3 Not used
MB(Toggle SW)
Note 2
UP
For make-busy
For normal operation
SW1 (Piano Key
SW)
1
For normal operation
OFF Not used
2
For normal operation
OFF Not used
3
For normal operation
OFF Not used
4
For normal operation
OFF
Not used
AP NO.
SW NO.
1004 05 06 07 08 09 11 12 13 14 15
456789ABCDEF
ON
DOWN
ON
OFF
4
3
2
1
ON
ON
ON
ON