user manual
CHAPTER 4 ND-45504 (E)
Page 56
Revision 2.0
PN-AP00-A (AP00)
SW0 (Dip SW)
1
Note 3
ON
Enables the receive clock from the DCE (Mo-
dem) side when the No. 0 Port is synchronous.
(Clock is received at the RXC terminal.)
OFF
• Uses the internal clock as the receive clock
when the No. 0 Port is synchronous
• When the No. 0 Port is asynchronous
2
ON
Enables transmit clock from the DCE (Mo-
dem) side when the No. 0 Port is synchronous.
(Clock is received at the TXC (2) terminal.)
OFF
• Uses the internal clock as the send clock
when the No. 0 Port is synchronous
• When the No. 0 Port is asynchronous
3
ON
For transmitting the send clock from the DTE
(this card) when the No. 0 Port is synchro-
nous. (Clock is transmitted from the TXC (1)
terminal.)
OFF
• For not transmitting the send clock from the
DTE (this card) side when the No. 0 Port is
synchronous
• When the No. 0 Port is asynchronous
4
ON When the No. 0 Port is asynchronous
OFF When the No. 0 Port is synchronous
Switch Settings (Continued)
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
1 2 3 4 5 6 7 8
ON