ND-45504 (E) CHAPTER 4
Page 51
Revision 2.0
PZ-PW86 (D) (PWR)
(3) Switch Settings
The figure in the SWITCH NAME column and the position in in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Switch Settings
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
MODE 1 Always set to OFF
2
Float charging, for sealed batteries (Normal
Setting).
OPTION: Periodic Equalize charging of
external vented batteries.
OFF
Flaot charging, for vented batteries only.
SW1 For turning AC power and the battery on
OFF
For turning AC power and the battery off
AC INPUT: 90 V - 138 V
DOWN
AC INPUT: 180 V - 264 V
SW102
PRESS
MOMENTARILY
To start each PIM on battery power, when
AC power is not provided (switch “SW”
must be ON)
SW301
1
ON CR Voltage: 75 Vrms
CR Voltage: 90 Vrms
2
Frequency: 20 Hz
OFF
Frequency: 25 Hz
ON
1
2
OFF
ON
OFF (O)
ON (I)
ON
240 VAC
100/120 VAC
UP
25Hz
1
2
OFF
90V
20Hz
ON
75V
OFF
ON