user manual

ND-45504 (E) CHAPTER 4
Page 25
Revision 2.0
PN-BS01-A (BS01)
(3) Switch Settings
The figure in the SWITCH NAME column and the position in in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.
Switch Settings
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
MB (Toggle SW)
Note
UP For make-busy
For normal operation
SW13 (Dip SW)
1, 5
ON Set SW13 according to the mounting location of this
card.
OFF
2, 6
ON
OFF
3, 7
ON
OFF
4, 8
ON
OFF
ON
DOWN
1 2 3 4 5 6 7 8
ON
SWITCH
No.
SW13
-1, 5
SW13
-2, 6
SW13
-3,7
SW13
-4, 8
MOUNTING
LOCATION
PIM1 ON OFF OFF OFF
PIM2, PIM3 OFF ON OFF OFF
PIM4, PIM5 OFF OFF ON OFF
PIM6, PIM7 OFF OFF OFF ON