user manual

ND-45504 (E) CHAPTER 4
Page 99
Revision 2.0
PN-SC03 (CSH)
(2) Lamp Indications
3. Switch Settings
The figure in the SWITCH NAME column and the position in in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Set the groove on the switch knob to the intended switch position.
Note 2:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
Lamp Indications on CSH Card
LAMP NAME COLOR FUNCTION
RUN Green Flashes at 120 IPM while the card is operating normally.
DOPE7 Green Lights when No.7 circuit D channel link is connected.
DOPE6 Green Lights when No.6 circuit D channel link is connected.
DOPE5 Green Lights when No.5 circuit D channel link is connected.
DOPE4 Green Lights when No.4 circuit D channel link is connected.
DOPE3 Green Lights when No.3 circuit D channel link is connected.
DOPE2 Green Lights when No.2 circuit D channel link is connected.
DOPE1 Green Lights when No.1 circuit D channel link is connected.
DOPE0 Green Lights when No.0 circuit D channel link is connected.
Switch Settings on CSH Card
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
SENSE
(Rotary SW)
Note 1
4 ~ F Set the switch to match the AP Number (04 ~ 15) to be set by CM05.
0 ~ 3 Not used
MB (Toggle SW)
Note 2
UP
For make-busy
For normal operation
AP No.
SW No.
1004 05 06 07 08 09 11 12 13 14 15
456 789ABCDEF
ON
DOWN