user manual

ND-45504 (E) CHAPTER 4
Page 95
Revision 2.0
PN-SC02 (ICH)
(3) Switch Settings
The figure in the SWITCH NAME column and the position in in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Set the groove on the switch knob to the desired switch position.
Note 2:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
Switch Settings
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
SENS
(Rotary SW)
Note 1
4 - F Set the switch to match the AP Number (04 - 15) to be set by CM05.
0 - 3 Not used
MB (Toggle SW)
Note 2
UP For make-busy
For normal operation
SW0
(Piano Key SW)
1 Always set to OFF
2 Always set to OFF
3 Always set to OFF
4
Always set to ON
AP NO.
SW NO.
1004 05 06 07 08 09 11 12 13 14 15
456789ABCDEF
ON
DOWN
ON
OFF
4
3
2
1
OFF
OFF
OFF