user manual

ND-45504 (E) CHAPTER 4
Page 89
Revision 2.0
PN-SC00 (CCH)
(3) Switch Settings
Switch Settings
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
SENS
(Rotary SW)
Note 1
4 - F Set the switch to match the AP Number (04 - 15) to be set by CM05.
0 - 3 Not used
MB(Toggle SW)
Note 2
UP For make-busy
For normal operation
SW0
(Piano Key SW)
1
ON Loop-back test
For normal operation
2
ON Analog interface
OFF Digital interface
3
ON
RS-232C RTS signal (to MODEM) ON
Note 3
OFF RS-232C RTS signal (to MODEM) OFF
4
Always set to ON
AP NO.
SW NO.
1004 05 06 07 08 09 11 12 13 14 15
456789ABCDEF
ON
DOWN
ON
OFF
4
3
2
1
OFF
ON