user manual
ND-45504 (E) CHAPTER 4
Page 83
Revision 2.0
PN-ME00 (EXTMEM)
(3) Switch Settings
The figure in the SWITCH NAME column and the position in in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Set the groove on the switch knob to the desired switch position.
Note 2:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
Note 3:
Do not touch the JP0. If the jumper is pulled off, the data in the memory of the ME00 card is cleared.
Switch Settings
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
SENSE
(Rotary SW)
Note 1
4 - F Set the switch to match the AP Number (04 - 15) to be set by
CM05.
0 - 3 Not used
MB(Toggle SW)
Note 2
UP For make-busy
For normal operation
JP0 (Jumper pin)
Note 3
For normal operation
JP2 (Jumper pin) For normal operation
AP NO.
SW NO.
1004 05 06 07 08 09 11 12 13 14 15
456 789ABCDEF
ON
DOWN
Front
UP
Front
UP