Electronics America Server User's Guide
Service Processor 3-27
EN (Environmental Information)
Execution:
This command can be executed in the AC POWER ON or DC POWER state.
Function:
Lists the states of the system’s detected temperature and fan errors, etc. The
components in the DC POWER OFF state are not supervised.
Note: The EN command can be executed in Normal mode or
Maintenance mode.
Table 3-30. EN Screen
Screen Image Reference
iSPyz:---> en<ENTER>
---- Power Box/Bay Units -------------------------------------------------- 19:20:57,01/31/2002 ----
state DPS0 DPS1 DPS2 DPS3 DPS4 DPS5
PBAY00 ON --- ---
PBAY01 ON --- ---
* EXT PBAY10 ON --- --- ALARM
----------------------------------------------------------------------------------------------------------------------
A
---- Main Chassis FANs ---------------------------------------------------- 19:20:57,01/31/2002 ----
CELL FR0 FF0 FR1 FF1
ALARM HIGH HIGH HIGH
XIC/XBR FRL FRR FR2 FF2
ALARM
PCIV0 FM0 FM1 FM2 FM3
ALARM
----------------------------------------------------------------------------------------------------------------------
B
Next page? (n[ext]/e[xit]/CR=next) : <ENTER>
C
---- CELL/XIC/XBR board DD-con/Temp alarm ---------------------- 19:20:57,01/31/2002 ----
state DD-con Temp
CELL0 ON
* CELL1 OFF ALARM
* CELL2 NORESP
* CELL3 OFF ALARM
* XIC OFF ALARM
* XBR NORESP
----------------------------------------------------------------------------------------------------------------------
D
---- PCIX-BOX DD-con/Temp/FAN alarm ------------------------------ 19:20:57,01/31/2002 ----
state DD-con Temp FAN Local/Remote
* PCIX0(V) ON ALARM ---
* PCIX1(F) OFF ALARM ALARM Remote
* PCIX2(F) ON --- ALARM Local
* PCIX3(F) OFF --- ALARM Remote
----------------------------------------------------------------------------------------------------------------------
E