User Manual

157
Chapter 8 Scanner Maintenance
8
Scanner Maintenance
is cleaned. (Figure 2d)
Replace the paper pad mechanism. Be sure you hear the paper pad mechanism ‘click’
back into place.
5. Clean the lower glass imager by gently wiping over the length of the glass image. (See
Figure 2 above)
Be extremely careful not to catch the plastic tab with your cloth.
Do NOT spray isopropyl alcohol or any other solvent into the scanner or anywhere on
the scanner.
6. Clean the upper glass imager by gently wiping over the length of the glass image. (See
Figure 2 above).
Be extremely careful not to catch the plastic tab with your cloth.
Do NOT spray isopropyl alcohol or any other solvent into the scanner or anywhere on
the scanner.
Use extreme caution when cleaning around the paper sensor (the small plastic arm
just above the upper glass imager).
7. Wait for cleaned areas to dry completely BEFORE closing the scanner cover.
8. Close the scanner cover by pushing it back down until it snaps back into place.