Reader Installation Instruction
NKY-5277-DL / P Series
NKY-5277 series are mullion sized surface mount readers with data output to communicate with a FERMAX 2430 relay decoder.
Data Bus to be wired using RS-485 twisted shielded cable.
Wiring Diagram
Operating Voltage
Voltage Tolerance
Current Draw
Operating Temperature
Humidity
Dimensions
12Vdc Only
±10%
12VDC/100mA
-10˚C~+45˚C
0~95%
43mm (W) x 97mm (L) x 19mm (D)
Installation Instructions
We recommend sealing the reader to the wall and the cable penetration from behind to mitigate against any moisture
ingress and insects.
Note
1. Remove the back plate from the unit
2. Drill 2 holes (A, C) on the wall for the screws and one hold for the cable (B)
3. Knock the supplied plugs into the screw holes (A, C)
4. Fix the back plate firmly on the wall with the 2 screws provided
5. Thread the cable through the cable hole (B) and terminate
6. Attach the unit to the back plate and screw the bottom lock screw in place (D)
nearkey
Ø10mm
84mm
49mm35mm
Ø4mm
Ø4mm
C
A
B
D
Reset Nearkey Configuration
To reset your nearkey reader to factory default settings, unscrew the bottom lock screw
and remove the unit from the back plate. On the rear of the unit at the bottom there is a
reset push button. With the unit still powered up press and hold the reset button for
5secs then release.
Reset Button
NKY-5277-DL
NKY-5277-P
(rear)
NKY-5277-DL
NKY-5277-P
Green:
Green:
Red:
Black:
White:
Blue:
Brown:
D1
D2
Yellow:
Orange:
Not Used
Constant 12Vdc
to FERMAX 2430
Power Input
Not Used
Data Bus