Daim Ntawv Qhia Tus Neeg Siv

Table Of Contents
Connect wifi
07
08 11
13
12
NDI|HX driver installation
09
Currently our encoders adopt compressed NewTek NDI|HX
technology. Before your using, clients need to download NDI
NDI|HX driver from https://www.newtek.com/ndi/tools/#.
Note:
1. Click the “Network and
Service Settings” menu on
the web interface to enter
the “Network Interface
Management” interface.
2. Select WiFi interface in
the WiFi group and
click“Configure” button to
enter the WIFI parameter
configuration interface.
3. Select hotspot to
connect from the scanned
hotspot list, click
"Connect", fill in necessary
password option on the
interface shown on the
right.
Restore factory settings
Hold the ‘Reset button more than 5 seconds, restoring factory setting
will lead to the device reboot, and restarting course will last about 20s.
Note:
The se par am ete rs w il l be res to red aft er res to rin g fa ct ory se tti ng :
Lo gi n us ern am e an d pa ss wor d w ill be a s ad mi n;
IP addre ss w il l be r es to red as 1 92. 16 8. 1.1 68 , su bne t m ask wil l b e
25 5.255 .2 55. 0;
Al l en cod in g pa ra met er s of vid eo a nd a ud io w il l be r es tor ed to f act or y
de fault val ue ;
Me dia trans mi ssi on p ar amete rs w il l be r es tored as f act or y de fa ult val ue .
Restore factory settings
Two methods for restoring factory settings:
If users change parameters that lead encoder couldnt work(The typical
situation is changed network address, so it couldnt be visited encoder by
network), users could restore factory setting to default value.
ChooseBasic Settings>Restore factory settingson the web console.
Press “Reset” button.
Quick reset and reboot
Quick Reset” function is to reset encoding service, normally used for making
changed parameters to effect immediately.
The whole process lasts around 3s.
Reboot” function is used for encoder reboot. Device rebooting lasts around 20s.
Quick reset and Reboot
Note:
Sel ec t Qui ck R es et,c ur ren t en co ding w ill be s us pen de d fo r a w hil e;
Sel ec t Reb oo t, the en cod er w il l w arm reb oo t.
Und er som e ci rc ums ta nces, reb oo t ma ybe wi th t he h el p of co ld
reb oo t: pow er d ow n th en p ow er u p th e de vi ce.
Firmware upgrading
Firmware upgrading
Thi s d evi ce s up por ts o nl ine fir mw are upg ra din g fo r up gradi ng s of twa re .
Sel ec tB as ic S et tin gs , p ull dow nw ard and cli ck Up da te f irm wa re ” .
On t he p ag e, c lic k Bro ws e” t o se lec t t he u pgr ad ing fil e, a nd c li ck Up gra de
to u pg rad e th e de vi ce.
Note:
After uploading firmware file successfully, the encoder will automatically restart,
this process will take about 30s-60s(the time will be different according to upgrade
content), and please be patient.
After the upgrade is complete, via the web interface”system information>version
information” to check whether the latest version information in accordance with
expected and confirm the upgrade succeeded.
NDI discovery and connection
®
It is compatible with NewTek NDI . When the device is in the
same network as the Studio Monitor software(others like OBS,
vMix, etc.), the device can be automatically discovered.
Mod ify N DI c han nel n ame
Encoder temporarily does not
support RTSP pull.When NDI is
connected, the default RTSP
channel of the main stream of
the encoder is encrypted, and
the direct pull-out will be
displayed as a mosaic state.
A NDI|HX driver is required to
install before streaming.
When there are several NDI
encoders in the same network,
as default Channel is the same,
clients needs to set different
Channels for different devices.
RTMP Live Streaming
10
Take YouTube for an example
Streaming point” is RTMP address given by platform ( Take YouTube as an example ).
( Other platforms are similar, if questions please contact platform technical support for help ).
RTMP push-flow must first get a push-flow URL address from the platform
Login to YouTube, got below address:
Streaming point should be like Server URL+Stream name/key,
for example: rtmp://a.rtmp.youtube.com/live2/9ja6-9u28-uz4j-8x6r
After you get the RTMP URL address, you need to set it up in the encoder.
If the platform requires user name and password verification, you also need
to fill in the corresponding parameters in the encoder.
In the case of rtmps push mode, fill in rtmps URL at Push point and set Use
old RTMP version to yes, so that it can be supported.
Note:
Add streaming service
Add RTMP pushing streaming service
Our device’s H.264 main/sub stream supports adding up to 8 same or different
streaming media service, to meet your needs of adopting same/different stream
media protocols for multi-goal pushing.
On the management interface of “Encoding&Stream-Encoding and Stream
Settings”, for main/sub stream to choose “add one stream service, users can
add the needed service type.
Currently main video live streaming platforms requireRTMP” service. After adding
RTMP pushing service, click set icon to configure RTMP parameters.
Note:
This i s an exa mp le o f R TM P t o in tr odu ce the co nfi gu ra tio n o f pu sh
flow. O th er p us h fl ow m et ho ds c an b e l ogi n t o th e de vi ce p ag e fo r de ta il ed
confi gu ra tio n.