NCR 7455 Retail Terminal Release 1.
The products described in this book are licensed products of NCR Corporation. NCR is a registered trademark of NCR Corporation. Pentium is a registered trademark of Intel Corporation. It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available. NCR, therefore, reserves the right to change specifications without prior notice. All features, functions, and operations described herein may not be marketed by NCR in all parts of the world.
Site Preparation i Preface Audience This book is written for hardware installer/service personnel, system integrators, and field engineers. Notice: This document is NCR proprietary information and is not to be disclosed or reproduced without consent. Safety Warnings This equipment is intended for use with an IT power system with a line-toline voltage of 240 V or less. Fuse Replacement Caution: For continued protection against risk of fire, replace only with the same type and ratings of fuse.
ii Site Preparation Lithium Battery Warning Caution: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type as recommended by the manufacturer. Discard used batteries according to the manufacturer's instructions. Attention: Il y a danger d'explosion s'il y a remplacement incorrect de la batterie. Remplacer uniquement avec une batterie du même type ou d'un type recommandé par le constructeur.
Site Preparation iii This book contains the information necessary for the preparation of a site that conforms to NCR specifications. It is very important that the site complies with the requirements specified in the document because, once the equipment has been installed, deficiencies in site preparation or the problems caused by these deficiencies are much more difficult to detect and correct.
iv Site Preparation Finally, only the customer can know the full extent of damage that may be caused to his business by reason of failure of the equipment which is to be installed. For this reason, it is the customer’s responsibility to ascertain the extent of any possible damage to his existing or planned business, and to effect full insurance in for all eventualities.
Site Preparation Table of Contents Introduction.........................................................................1 Interpreting the Model Number.......................................2 Related Site Preparation Data ...........................................3 How to Order ......................................................................
vi Site Preparation NCR 5972 2x20 Remote Post Customer Display....17 NCR 5973 International Remote Post Customer Display.........................................................................18 NCR 5972 Remote Table-Top Customer Display ..19 NCR 2336-K007 External CD-ROM Drive ..............20 NCR 2336-K008 USB RS-232 Port Server ................20 Component Weights.........................................................21 Ventilation Clearance .......................................................
Site Preparation AC Power Line Transient Protection 1 Data Line Transient Protection .........................................
viii Site Preparation Revision Record Issue Date Remarks A April 01 First issue
Site Preparation ix Radio Frequency Interference Statements Federal Communications Commission (FCC) Information to User This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
x Site Preparation Declaration of Conformity Manufacturer’s Name NCR Corporation Manufacturer’s Address NCR Corporation Retail Solutions Division 2651 Satellite Boulevard Duluth, GA 30096-5810 Type of Equipment Information Technology Equipment Model Number Class 7455 Electrical Ratings (Input) 100-240 V, 2.
Site Preparation Introduction 7 4 1 8 5 2 9 6 3 0 18427 This document provides the information necessary to prepare a site to NCR specifications prior to installing a terminal. The site must be properly prepared before the retail terminal is installed because site preparation deficiencies may be difficult to detect and correct after installation. The terminal consists of separate pieces that may be combined in a variety of configurations. Certain combinations are mutually exclusive.
2 Site Preparation Interpreting the Model Number NCR Model 74xx 22 XX 80 01 Language 01 = International English Power Required 80 = 110 -240 VAC 50/60 Hz Operating System 00 = No OS 01 = Windows 03 = MS/DOS Processor 22 = Base Unit with 12.
Site Preparation Related Site Preparation Data AC Power and Communications Wiring Title Order Number NCR Ethernet Communications Wiring Guide BST0-2118-82 NCR Terminal AC Power Wiring Guidelines BST0-2115-53 Peripherals Title Order Number NCR 7158 Thermal Receipt/Impact Printer B005-0000-1112 NCR 7162 Thermal Receipt Printer Owner’s Guide B005-0000-1067 NCR 7166 Thermal Receipt/Impact Printer B005-0000-1002 NCR 7194 Thermal Receipt Printer Owner’s Guide B005-0000-1094 NCR 7196 Thermal Recei
4 Site Preparation How to Order Information Products are available through several different channels. You need an order form if you are using fax, e-mail, or mail order. Order forms are available to NCR personnel through QuickLook. In QuickLook, click on Forms & Templates, then select Information Products Order Form. Web Sites • http://inforetail.AtlantaGA.NCR.COM (NCR only) • http://www.info.NCR.
Site Preparation 5 Customer Responsibilities Before the system can be installed, the customer must do or provide the following: • When required by NCR, provide the NCR Customer Services representative with appropriate drawings that indicate: − Location of the equipment − Site wiring (power and communications, paths and lengths) − Location of other equipment that may generate electrical noise, electromagnetic interference, or heat.
6 Site Preparation AC Store Wiring Requirements The customer must provide suitable AC power for the retail terminals, associated equipment, and devices. A dedicated unswitched power line dedicated to the NCR equipment installation is recommended. Refer to the Workstation and Peripherals AC Wiring Guide (BSTO2115-53) for store AC wiring requirements. The AC outlet must be installed near the retail terminal and easily accessible to the operator.
Site Preparation 7 System Configuration Diagram NOTE: 7837 connect to RS-232 or Wedge 7837 Serial Only 7448 Customer Display 5972-1000 Customer Display 5972-2000 Customer Display 5973 International Customer Display PS/2 or USB Keyboard CRT Operator or Customer Display Parallel/ PS/2 LCD Wedge VGA Serial KBD * NOTE: 7158 & 7196 connect to RS-232 or USB Aux Power RS-232 Transaction Printers * Aux Power Parallel 7 * 4 USB 7194 7196 7166 7158 7454-K005 7875 Scanner/Scale Cash Drawer RS-23
8 Site Preparation Physical Considerations This section presents the following retail terminal information: • Operating and service clearance requirements • Display mounting considerations • Retail terminal and component dimensions • Component weights • Airflow requirements • Power requirements
Site Preparation Operating and Service Clearance Requirements Location Component Distance Reason Above 7158 Printer 305 mm (12 in.) Clearance to raise printer cover 7162 Printer 197 mm (7.75 in.) Clearance to raise printer cover 7166 Printer 280 mm (11 in.) Clearance to raise printer cover 7194 Printer 228 mm (9 in.) Clearance to raise printer cover 7196 Printer 254 mm (10 in) Clearance to raise printer cover CRT Displays 50 mm (2 in.
10 Site Preparation Component Dimensions NCR 7455 with Integrated Customer Display and PCMCIA 475 mm (18.7 in.) 445 mm (17.5 in.) 7 8 9 4 5 6 1 2 3 380 mm (15.0 in.) 466 mm (18.3 in.
Site Preparation 11 NCR 7455 with Integrated Post Customer Display 475 mm (18.7 in.) 7 8 9 4 5 6 1 2 3 480 mm (19.0 in.) 406 mm (16.0 in.) 18817 7453-K005 Cash Drawer 455.6 mm ( 17.94in.) 108 mm (4.25 in.) 450.9 mm (17.75 in.) 263.5 mm (10.375 in.
12 Site Preparation NCR 2189 Cash Drawer 464 mm (18.25 in.) 133 mm (5.25 in.) 527 mm (20.5 in.) 330 mm Operating and (13 in.) Service Clearance for Drawer 16676 NCR 2113 Cash Drawer 400 mm (15.75 in.) 96 mm (3.75 in.) 450 mm (17.75 in.) 254 mm (10 in.
Site Preparation 13 NCR 7162 Receipt Printer 148mm (5.5 in.) 240 mm (9.45 in.) 165 mm (6.5 in.) 16099 NCR 7194 Thermal Receipt Printer 212 mm (8.3 in.) 130 mm (5.10 in.) 85 mm (3.30 in.) 157 mm (6.20 in.) 187 mm (7.4 in.
14 Site Preparation NCR 7166 Thermal Receipt/Impact Printer 171 mm (6.75 in.) 280 mm (11.00 in.) 248 mm (9.75 in.) 330 mm (13.00 in.) 17308 NCR 7158 Thermal Receipt/Impact Printer 165 mm (6.50 in.) 305 mm (12.00 in.) 336 mm (13.25 in) 229 mm (9.
Site Preparation 15 NCR 7196 Thermal Receipt Printer 146 mm (5.75 in.) 108 mm (4.25 in.) 254 mm (10.00 in.) 140 m (5.50 in.
16 Site Preparation NCR 7455 - 4x20 Remote Post Customer Display 180 mm (7 in.) 50 mm (3.5 in.) 110 mm (4.25 in.) 506 mm (22.1 in.) 95 mm (3.75 in.) 95 mm (3.75 in.
Site Preparation 17 NCR 5972 2x20 Remote Post Customer Display 262 mm (10.3 in.) 30 mm (1.2 in.) 119 mm (4.7 in.) 506 mm (22.1 in.) 95 mm (3.75 in.) 95 mm (3.75 in.
18 Site Preparation NCR 5973 International Remote Post Customer Display 262 mm (10.3 in.) 45 mm (1.8 in.) 110 mm (4.3 in.) 350 mm (13.8 in.) 95 mm (3.75 in.) 95 mm (3.75 in.
Site Preparation 19 NCR 5972 Remote Table-Top Customer Display 262 mm (10.3 in.) 110 mm (4.3 in.) 45 mm (1.8 in.) 158 mm (6.2 in.) 178 mm (7.0 in.) 173 mm (6.8 in.
20 Site Preparation NCR 2336-K007 External CD-ROM Drive 155 mm (6.1 in.) 218 mm (8.6 in.) 23 mm (0.9 in.) 16951 Note: Allow 75 mm (3 in.) clearance in the back of the NCR 2336-K007 External CD-ROM Drive for connector and cable clearance. NCR 2336-K008 USB RS-232 Port Server 183 mm (7.2 in.) 111 mm (4.4 in.) 26 mm (1.0 in.
Site Preparation Component Weights The following table shows the component weights for each integrated component. Retail Terminal Components Weight kg. lbs. 2189 Cash Drawer 9.5 20.9 7453-K005 Cash Drawer 11.4 25.15 7455 4x20 Remote Customer Display 0.7 1.5 7158 Receipt/Impact Printer 4.8 10.5 7162 Receipt Only Printer 1.7 3.8 7166 Receipt/Impact Printer 5.6 12.3 7194 Thermal Receipt Printer 1.3 2.8 7196 Thermal Receipt Printer 1.8 3.4 2336-K007 External CD-ROM Drive 0.6 1.
22 Site Preparation Ventilation Clearance Leave the minimum clearances shown below for proper cooling conditions for the 7455 Class Retail Terminal. 25 mm (1 in.) 76 mm (3 in.
Site Preparation 23 Power Requirements Core module contain a three-wire, single-phase, selectable 120/240 volt AC, 95 Watt power supply. The supply powers the retail terminal, DynaKey, MSR, some scanner, VFD display, keyboard, USB interface, cash drawer, and PCMCIA cards. The following tables show operating specifications for the power supply. Maximum Input Power Specifications 120 volt Voltage Ranges Frequency Current (A) Power (W) Power Factor (typical) 90 - 136 VAC 50/60 Hz 1.0 90 0.
24 Site Preparation Cable Routing Considerations External cables can be routed out the back of the Table-Top Mount. The internal cable connectors on the terminal are located on the underside of the Core Module under the Cable Cover.
Site Preparation 25 Considerations for Enclosed Installations Thermal Test Points With the terminal installed in the enclosure, verify that the temperature does not exceed 45o C (115o F) in the operating environment. Test the temperature at the rear access panel covering the CD-ROM and hard drive. 18820 Note: For terminal servicing information refer to NCR 7455 Retail Terminal Hardware Installation & Service (B005-0000-1285).
26 Site Preparation System Cables Cable Type Cable Name Cash Drawer Dual Drawer, Y cable Communications Ethernet, 10/100Base-T NCR Part No. 497-0409394 497-0008623 (Unshielded) USB 497-0415949 USB 497-0415950 Displays Remote Customer Display 497-0418248 (Parallel Interface) 497-0415249 2x20 Customer Display (RS-232 Interface) 497-0411000 Parallel I/F Cable (adapter cable) Power U.S. – Straight 006-1009037 U.S. – Twist-lock 250-0023191 Intl. – Straight ‘BM’ Power 006-8601010 Intl.
Site Preparation Cable Type Cable Name Printer Extender 7162/7166/7196 Drop Cables Printer/Workstation (7453-K641) 7194 Printer Printer Power 7194 Printer Supply 27 NCR Part No. Corp.
28 Site Preparation Cable Illustrations Dual Cash Drawer, Y-cable Cash DWR. #1 497-0409394 Cash DWR. #2 16 mm (0.625 in.) Access Hole Diameters 51 mm (2.0 in.) 15808 Ethernet, 10/100 Base-T Modular 8-Pin Plug Modular 8-Pin Plug 497-0008623 19 mm (.75 in.) USB, 1- or 4-Meter Access Hole Diameters 19 mm (.75 in.
Site Preparation 29 Printer Interface Cables (RS-232) 7162/7166/7196 9-pin D-shell Receptacle 497-0407427 - 1 m 497-0407429 - 4 m 497-0407430 - 15 m 25-pin D-shell Plug Workstation RS-232 Port Printer 38 mm (1.5 in.) Access Hole Diameters 63.5 mm (2.5 in.) 13224 7194/7158 9-pin D-shell Receptacle 497-0408349 - 0.7 m 497-0407943 - 4 m 497-0409379 - 15 m 9-pin D-shell Receptacle Workstation RS-232 Port Printer 38 mm (1.5 in.) Access Hole Diameters 38 mm (1.5 in.
30 Site Preparation NCR 5972 Remote Customer Display and Adapter Cables Parallel I/F Cable 497-0411000 - 0.6 M To Cust. Display Port 25-pin D-Shell Receptacle 497-0405676 - 4 M 1416-C278-0040 24-pin Microfit Receptacle To Customer Display 8-pin Microfit Receptacle To Power Brick Access Hole Diameters 57.1 mm (2.25 in.) 19 mm (0.75 in.) 25 mm (1.0 in.
Site Preparation External CD-ROM Cable 25-pin D-Shell Receptacle 497-0413011 - 0.6 M 1416-C464-0006 28-pin Sub-Miniture D-Plug To 7455 Cust. Display Port To CD-ROM Parallel Connector SMK 2 mm Plug To CD-ROM Power Connector Access Hole Diameters 57 mm (2.25 in.) 12 mm (0.5 in.) 31 mm (1.25 in.) 16959 External Parallel Cable 25-pin D-Shell Receptacle 497-0411000-0.6 M 1416-C472-0006 28-pin Sub-Miniture D-Plug To 7455 Cust. Display Port To CD-ROM Parallel Connector Access Hole Diameters 57 mm (2.
32 Site Preparation Automatic Change Dispenser Serial Cable P1 5 9 1 6 P2 497-0404832 9-Pin D-shell Receptacle 25-pin D-shell Plug 1 14 13 25 18056 Power, AC 006-1009037 Workstation Access Hole Diameter 45 mm (1.75 in.
Site Preparation 33 Environmental Requirements Barometric Pressure The 7455 Retail Terminal is designed to operate within the following barometric pressure conditions: • Maximum operating altitude: 3000 m (9843 ft) • Operating range of pressure: 105 kPa to 69 kPa (15.2 lb/in. to 10.0 lb/in.) Temperature The 7455 Retail Terminal is designed to operate over the temperature ranges shown below.
34 Site Preparation
Appendix A: Transient Protection AC Power Line Transient Protection In the process of power distribution, transient electrical energy (including, but not limited to, lightning strikes, intermittent short circuits, and switching transients) can be introduced onto power lines. Such transient energy can be very damaging to electronic hardware, and can also cause data corruption. Under these circumstances, NCR recommends the use of AC power transient suppressors.
A-2 Appendix A: Transient Protection • Be listed by the accepted safety organization for the country involved (UL, CSA, VDE, ETL, and so on) and the installation must conform to local, state, and national electrical codes and regulations. Data Line Transient Protection The nature of the transient phenomenon may extend to the data communication lines connected to this equipment.
Index A-i Index —2— 2336-K007 External CD-ROM Drive, 20 2336-K008 USB RS-232 Port Server, 20 —4— 4x20 Remote Customer Display, 16 —5— 5972-1000 Remote Customer Display, 17 5973 International VFD Customer Display, 18, 19 —7— 7158 Thermal Receipt/Impact Printer, 14 7161 Thermal Receipt Printer, 13 7166 Thermal Receipt/Impact Printer, 14 7194 Thermal Receipt Printer, 13 7196 Thermal Receipt Printer, 15 7453-K005 Cash Drawer, 11 —A— ACD Serial Cable, 32 —C— Cable Illustrations, 28 Cable Routing Consider
ii Index —N— NCR 2113 Cash Drawer, 12 NCR 2189 Cash Drawer, 12 —O— Operating range of barometric pressure, 33 —P— Power requirements, 23 Printer 7158 Thermal Receipt/Impact Printer, 14 7161 Thermal Receipt Printer, 13 7166 Thermal Receipt/Impact Printer, 14 7194 Thermal Receipt Printer, 13 7196 Thermal Receipt Printer, 15 Printer Interface Cables (RS-232), 29 —R— Remote Customer Display, 17 Remote Customer Display and Adapter Cables, 30 RS-232 Port Server, 20 —S— Service Access, 25 —T— Temperature,