RealScan 7883 Installation and Owner Guide 12623 497-0424789 Release F April 2004 Information Products RSD-Atlanta
NCR RealScan 7883 Installation and Owner Guide The program products described in this book are licensed products of NCR Corporation. It is the policy of NCR to improve products as new technology, components, software, and firmware become available. Therefore, NCR reserves the right to change specifications without prior notice. All features, functions, and operations described herein may not be marketed by NCR in all parts of the world.
NCR RealScan 7883 Installation and Owner Guide NCR Components ........................................................................................................ 39 METTLER TOLEDO Components............................................................................. 40 Sensormatic Components ............................................................................................ 40 System Construction ................................................................................................
NCR RealScan 7883 Installation and Owner Guide Hex E ........................................................................................................................... 75 Hex F ........................................................................................................................... 75 Revision Record 4 of 75 Date Pages Issue Remarks 02-02 07-02 09-02 All All All A B C 10-02 09-03 59-72 All D E 04-04 All F First printing. Updated to match latest units.
NCR RealScan 7883 Installation and Owner Guide Obtaining Additional Information Other Information Products Order Number Title B005-0000-1436 B005-0000-1437 BST0-2121-74 BD20-1074-A NCR RealScan 7883 User Guide NCR RealScan 7883 Repair Guide NCR Scanner Programming Tags NCR Scanner/Scale Interface Programmer’s Guide How To Obtain Information Products Web Sites • http://inforetail.AtlantaGA.NCR. COM (NCR only) • http://www.info.NCR.
NCR RealScan 7883 Installation and Owner Guide NCR RealScan 7883 Mountings The NCR RealScan 7883 Scanner is a small, compact laser scanner available in two models. The RealScan 7883-1000 has many of the same features found in larger scanners. The RealScan 7883-1200 has the same capabilities as the 7883-1000; however, it uses the new Super ASIC technology. The RealScan 7883 can be mounted horizontally in a checkstand or vertically above the checkstand. Various mounts are available for the RealScan 7883.
NCR RealScan 7883 Installation and Owner Guide Installation Instructions When installing a RealScan 7883, it is recommended that you first mount the Power Supply and run all the cables. After connecting the unit to the host terminal, make any necessary programming changes and scan some good tags to verify that the scanner is communicating with the host terminal. After verifying that everything is working correctly, mount the unit in the checkstand.
NCR RealScan 7883 Installation and Owner Guide Step 1 - Installing Power Supply and Interface Cables Connecting the Cables to an NCR RealScan 7883 The NCR RealScan 7883 is powered through an external Power Supply. An interface cable connects the RealScan 7883 to the host terminal. Two RS-232 peripheral ports are provided for connecting other devices such as an NCR 7837 HandHeld Scanner. Note: If you are using a Keyboard Wedge cable, it must be plugged directly into the PS/2 port on the PC.
NCR RealScan 7883 Installation and Owner Guide 7883-1000 USB Interface Connection Connecting a RealScan 7883-1000 Scanner to a USB port on a host terminal requires a special cable. One end of the Dongle Adapter Cable connects to the host terminal. The other end has an Interface Box that contains a printed circuit board with all the necessary circuitry. The host terminal supplies power for this circuitry. An Interface cable connects the scanner to this box.
NCR RealScan 7883 Installation and Owner Guide J3 in the Interface Box on the end of the Dongle Adapter Cable contains a shunt that must be correctly installed for the host terminal. The cable is shipped from the factory with a shunt on pins 3 and 4. The following four positions are available. • Pins 1 & 2 – Wedge • Pins 3 & 4 – IBM • Pins 5 & 6 – RS-232 • Pins 7 & 8 – HID The cover on the Interface Box latches together along one side. Carefully pry open the latched edge to open the Interface Box.
NCR RealScan 7883 Installation and Owner Guide For connecting to IBM and NCR terminals a latching or USB Plus Power cable should be used. 1416-C895-0050 - Cable - USB IBM, Latching For connecting to PC’s, non-NCR/IBM terminals and NCR terminals without the USB Plus Power connector use cable below. 1416-C896-0050 - Cable-USB. Detachable Auxiliary RS-232 Port The NCR RealScan 7883 includes two Auxiliary RS-232 Peripheral Ports.
NCR RealScan 7883 Installation and Owner Guide Special Installations RS-232 Peripherals The RealScan 7883 includes two auxiliary RS-232 ports. This permits other peripheral devices to connect to the host terminal through the RealScan 7883, eliminating the need of the host terminal having additional RS-232 ports. Programming of the ports is required. The various sequences and the action taken is given below for handheld scanners.
NCR RealScan 7883 Installation and Owner Guide the RealScan 7883. Programming the RealScan 7892 Set the RealScan 7892 communication parameters to match the requirements of the RealScan 7883 auxiliary port.
NCR RealScan 7883 Installation and Owner Guide FACTORY DEFAULT 1. RS232, 7 DATA, 1 STOP, SPACE PARITY 2. Prefixes / Code 39 - a, Code 128 - f, Code I 2of 5 - b 3. Default Data Format 1. UPC-A Prefix A 2. UPC-E Prefix E 3. EAN 13 Prefix F 4. EAN 8 Prefix FF 5.
NCR RealScan 7883 Installation and Owner Guide Step 2 - Setting Program Parameters and Verifying Host Connection Now you need to turn on the NCR RealScan 7883. First load new firmware if needed then make any necessary program changes. Next scan a few tags to verify that the RealScan 7883 is communicating with the host terminal. Note: The NCR 7883-1000 firmware cannot be flash. Only the NCR 7883-1200 firmware can be flash. Turning on the RealScan 7883 The RealScan 7883 does not have an On/Off switch.
NCR RealScan 7883 Installation and Owner Guide Programming Defaults Scanning the Default programming tag sets most program parameters to the default programmed at the factory. The original defined default values are shown in the chart below. However, some parameters do not have default values so they are not changed, they stay as they are programmed.
NCR RealScan 7883 Installation and Owner Guide 18 Bar Codes – 5 RSS Enable Scans Required On RSS 14 Scans Required On RSS E UCC1128 Emulation Mode Disable 1 1 Normal Mode 16 Label Identifiers Identifier Type Common Byte 1 Common Byte 2 Bar Code Type Default Prefix 5D 42 No Default value – remains as programmed UPC-A Common Byte Unique Identifier UPC-E EAN-8 EAN-13 Code 39 Code 128 I 2 of 5 0 0 0 0 2 2 2 41 Hex 45 Hex 46 Hex 46 Hex 31 Hex 33 Hex 32 Hex 20 RS-232 Parameters – 1 Baud Rate Parity
NCR RealScan 7883 Installation and Owner Guide Programming for USB Connection The RealScan 7883 Scanner must be properly programmed for USB. Programming and cabling depends on whether the unit is a 7883-1000 or 7883-1200. The 7883-1000 uses the USB Dongle connection to the host terminal while the 78831200 uses a straight through cable. The programming also depends on the type of host terminal being used. RS-232 Communications The 7883-1000 communicates with the USB dongle using RS-232.
NCR RealScan 7883 Installation and Owner Guide 3. 4. 5. 6. Hex 1, Hex 0, Hex D - sets the communication protocol to IBM USB. Hex 4, Hex 8, Hex 5 – turns off configuration message processing. Change any other parameters as required by the host terminal. Save and Reset – saves the parameters just entered and resets the RealScan 7883 Scanner Reduced Space Symbology Reduced Space Symbology (RSS) permits more data to be recorded in a smaller physical space.
NCR RealScan 7883 Installation and Owner Guide 0192 1234 5698 7457 3202 0000 9939 0200 296 19257 Enabling RSS 1. 2. Turn on the circuit breaker to the RealScan 7883. Enable the Reduced Space Symbology feature by scanning the following sequence of programming tags. These must be the first tags scanned after applying power to the unit. • Programming Mode - Puts the RealScan 7883 in the Programming Mode. • Hex 1, Hex 8, Hex A, Hex 3. • Save and Reset - Saves the parameter setting. 1. 2.
NCR RealScan 7883 Installation and Owner Guide Scan Sample Tags Now you should scan some sample tags to verify that the RealScan 7883 is communicating with the host terminal. Following are four good tags that you can use. After verifying that the RealScan 7883 is communicating properly with the host terminal, continue with the installation. Note: For maximum performance, full size labels must be used. The UPC Symbol Specification Manual gives the exact size requirements for UPC labels.
NCR RealScan 7883 Installation and Owner Guide Determining Label Quality Many labels in a typical retail environment are unreadable. The following illustration shows some of the common problems. Vendors and printers regularly supply products to the market with bar codes that are overprinted, underprinted, or truncated. Some labels have missing margins. Others may be printed around the corners of packages, or on media not likely to remain flat when picked up.
NCR RealScan 7883 Installation and Owner Guide Step 3 - Setting RealScan 7883 Scan Zone The scan zone on a NCR RealScan 7883 Scanner can be set to horizontal or vertical. Changing the scan zone changes the angle of the scan lines coming from the scanner. Vertical Scanning Horizontal Scanning 16011 You change the scan zone by turning the screw on the bottom of the cabinet. Be sure to turn the screw all the way in one direction or the other, do not leave it turned part way.
NCR RealScan 7883 Installation and Owner Guide Horizontal - Pass-by Scanning This installation provides the most efficient way to scan items. It is typically used in checkouts where speed is extremely important. In this installation, the operator slides items from the input area on the checkstand, across the scanner, and to the output area on the checkstand.
NCR RealScan 7883 Installation and Owner Guide Vertical - Presentation Scanning from Top This installation is used on small checkout counters that do not have enough room for pass-by scanning. Here the operator picks up the item, presents it toward the top of the scanner, and then bags the item all in one motion. Typical Installation Specialty Store Scan Zone - Vertical Installation - Vertical 16014 Vertical - Presentation Scanning from Bottom This installation is used on very small checkout counters.
NCR RealScan 7883 Installation and Owner Guide Step 4 - Mounting the RealScan 7883 The RealScan 7883 can sit vertically on the checkstand, be mounted vertically in a Vertical Mounting Bracket, or be mounted horizontally in the checkstand. If it is mounted horizontally in the checkstand, it must be fastened to a Plastic Top Plate, or possibly be positioned underneath a glass surface. The plastic scan window in the RealScan 7883 cabinet is not designed to have items slid over it.
NCR RealScan 7883 Installation and Owner Guide 3. Install two Latch Clips – horizontal installation only. These clips secure the RealScan 7883 to the Plastic Top Plate in case something falls on the assembled unit.
NCR RealScan 7883 Installation and Owner Guide Vertical Mounting Bracket Scanner Vertical Mount Bracket Laser Scan Direction Mounting Screws (Three) Interface Cable Power Cable Ground Wire RS-232 Peripheral Cable Laser Scan Direction Laser Scan Direction 16016 28 of 75 04/04 497-0424789 Release F
NCR RealScan 7883 Installation and Owner Guide Checkstand Cutout 1. 2. Low Surface Put the RealScan 7883 into the hole in the checkstand. Diagrams in NCR RealScan 7883 Specifications show the various dimensions of the hole. Align the RealScan 7883 to the Checkstand. The leading edge of the Top Plate must be flush or up to 1/16 in. (0.15 cm) below the top of the checkstand. The trailing edge of the Top Plate must be flush or up to 1/16 in. (0.15 cm) above the top of the checkstand.
NCR RealScan 7883 Installation and Owner Guide Operating the Scanner The NCR RealScan 7883 is a fixed position device that is not handled or moved by the operator during operation. It is maintained and serviced by trained service personnel only. The operator has no access to any laser module components. The RealScan 7883 does not have a power switch. However, you turn it on and off by using the circuit breaker switch, located in the checkstand, that supplies power to the unit.
NCR RealScan 7883 Installation and Owner Guide Cleaning the Scanner Keeping the scan windows clean helps keep the read rate exceptionally high. During normal operation the scan windows get dirty, and if you permit the dirt to accumulate, performance degrades to the point where the scanner cannot read bar codes. Use a soft cloth to clean the scan windows, using a common, non-abrasive, liquid window cleaner. Be sure to spray the cleaner onto the cloth, not directly onto the scanner.
NCR RealScan 7883 Installation and Owner Guide Correcting Scanner Problems When the RealScan 7883 is first turned on, several diagnostic tests are run to check the status of various components. If a failure occurs, a series of beeps and flashes of the Green Status Indicator identify it. The number of beeps (flashes) identifies the problem. The problem indication is repeated continuously with a 3-second pause between each indication series.
NCR RealScan 7883 Installation and Owner Guide There are other conditions that are not identified by the diagnostics when you turn on the RealScan 7883. The following chart identifies some of the more common problems.
NCR RealScan 7883 Installation and Owner Guide Interface Information Interface Connector Complies with FDA radiation Performance standards 21 CFR Subchapter J. VCCI-1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation.
NCR RealScan 7883 Installation and Owner Guide Communications Protocol The Communications Protocol function identifies the communications protocol the RealScan 7883 is using. Scan the Diagnostics Mode and Hex 3 programming tags (must be first tags scanned after applying power). Three beeps sound after scanning the Hex 3 tag, identifying the programming tag. Next, the Status Indicator flashes green and a series of beeps sound that identify the communications protocol.
NCR RealScan 7883 Installation and Owner Guide NCR RealScan 7883 Specifications Checkstand Hole – RealScan 7883 Horizontal Mount A B Item Flow B D D C C E E SIDE VIEW Features F062 K011 (7852 Mount) K010 (7820 Mount) A B C D E 8 5/8 in. 21.91 cm 9 5/8 in. 24.45 cm 20 1/8 in. 51.12 cm 8 5/8 in. 21.91 cm 11 5/16 in. 28.73 cm 11 5/8 in. 29.53 cm 1/16 in. 0.16 cm 1/16 in. 0.16 cm 1/16 in. 0.16 cm 1 1/16 in. 2.70 cm 1 1/16 in. 2.70 cm 13/32 in. 1.03 cm 1/2 in. 1.27 cm 1/2 in. 1.
NCR RealScan 7883 Installation and Owner Guide Checkstand Hole – RealScan 7883 Flat Mount A B Item Flow B D D C C SIDE VIEW Features K012 A 8 3/4 in. 22.22 cm B 8 3/4 in. 22.22 cm C 1/16 in. 0.16 cm D 1/16 in. 0.16 cm 11993 Ventilation Requirements The NCR RealScan 7883 is designed to operate without an exhaust fan in the checkstand; however, there must be adequate convection air flow. The ambient temperature inside the checkstand cannot be higher than 104° F (40° C).
NCR RealScan 7883 Installation and Owner Guide Electrical Wiring Input Voltage L3 G Main Service Panel Belt Control Lighting Misc. Equip. N Conduit Circuit A: Checkstand Belt Motor Checkstand Frame Note: The electrical wiring must meet all electrical codes, laws, and regulations. Neutral and Ground Bus Feeder wiring and insulated ground from main service panel to distribution panel to be run in metal conduit.
NCR RealScan 7883 Installation and Owner Guide NCR RealScan 7883, METTLER TOLEDO® Scale, & Sensormatic ScanMaxTMHS 20203 The NCR RealScan 7883, METTLER TOLEDO® 8217AS, & Sensormatic ScanMaxTMHS system is composed of components from three companies. NCR manufactures the scanner, METTLER TOLEDO manufactures the scale, and Sensormatic manufactures the tag deactivation system.
NCR RealScan 7883 Installation and Owner Guide METTLER TOLEDO Components Mounting Bracket With Scale Attached Top Plate Bridge Plate 20206 Sensormatic Components Controller Box Deactivation Brick Key Switch Alarm Box AC Power Cord 20207 40 of 75 04/04 497-0424789 Release F
NCR RealScan 7883 Installation and Owner Guide System Construction The NCR RealScan 7883, METTLER TOLEDO® Scale, & ScanMaxTMHS system can be constructed for right-to-left scanning or for left-to-right scanning. This is accomplished through the orientation of the Bridge Plate within the scale unit.
NCR RealScan 7883 Installation and Owner Guide Configuring the Scale First determine if the system needs to be configured for scanning from right-to-left or from left-to-right. Install the Bridge Plate on the scale unit inside the Mounting Bracket accordingly.
NCR RealScan 7883 Installation and Owner Guide Installing the Scanner 1. Using the Velcro Strips provided by NCR, attach the Key Switch Alarm Box to the RealScan 7883 as shown. Note: The top of the Key Switch Alarm Box must be below the top of the RealScan 7883. Refer to the illustrations under Configuring the Scale. 2. Connect the Power Cable, Interface Cable, and the Scale Cable to the RealScan 7883. Interface Cable Power Cable Key Switch Alarm Box Scale Cable 20212 3.
NCR RealScan 7883 Installation and Owner Guide Connecting Sensormatic Components 1. Position the Deactivation Brick on top of the Bridge Plate as shown under Configuring the Scale. The cable from the Deactivation Brick must be routed from the bottom of the brick toward the center of the Bridge Plate. Deactivation Brick Cable 20214 2. Connect the cables to the Controller Box.
NCR RealScan 7883 Installation and Owner Guide Routing the Cables How the cables are routed depends on the configuration, right-to-left or left-to-right scanning. In either case the cables are held in place with a cable clamp attached to the Bridge Plate.
NCR RealScan 7883 Installation and Owner Guide Left-To-Right Scanning Customer End 20218 Checkout System End 20219 Completing the Installation Position the unit inside the cutout in the self-checkout terminal. Then install the Top Plate. The Top Plate must positioned correctly for the type of scanning. Refer to Configuring the Scale.
NCR RealScan 7883 Installation and Owner Guide Calibrating the METTLER TOLEDO® Scale Before proceeding make sure the scanner is configured for a scale. The programming tag sequence below. If speech is enabled, the 7883-1200 will speak that the Scale Failed if the scale is not connected or not calibrated and the scanner is configured for a scale. The scanner may also have to be set for the proper weight.
NCR RealScan 7883 Installation and Owner Guide Depress the Zero Scale button or scan the Reset Scale tag. Two short beeps per second start to sound. 6. Place 20 pounds (or 10kg) on the Top Plate. 7. Depress the Zero Scale button or scan the Reset Scale tag. One long beep per second starts to sound. 8. Remove the 20 pounds (or 10 kg) from the Top Plate. 9. Depress the Zero Scale button or scan the Reset Scale tag. All beeps stop. 10. Replace the Calibration Switch Cover Screw. 11. Scan the Reset Scale tag.
NCR RealScan 7883 Installation and Owner Guide Sensormatic Deactivation Indicators The Key Switch Alarm Box that is fastened to the RealScan 7883 with Velcro strips, contains two indicators to indicate the status of the unit. • • • Solid Green – Unit has received an interlock signal. Flashing Green – Unit has power. Flashing Red – Unit is deactivating a tag.
NCR RealScan 7883 Installation and Owner Guide Troubleshooting For the most part, the function of each of the three units; scanner, scale, and deactivation unit; work independently from each other. However, there are some interactions. Following are some basic things to check if the system is not working properly. You may need to refer to the manufacturer's documentation for each unit. Scanner Problems If the scanner does not operate, check the following. • • • • • Power Cable connections.
NCR RealScan 7883 Installation and Owner Guide Position 1 Down Position 2 – 8 Up for 30.00 lb, Only position 3 Down for 15.000 kg Sensormatic Deactivation If the Sensormatic deactivation is not working, check the following. • • • • • • 497-0424789 Release F Controller Box Power Cable connections. Scanner Power Cable connections. Deactivation Brick Cable connection. Key Switch Alarm Box Cable connections. Interlock Cable connection (from RealScan 7883).
NCR RealScan 7883 Installation and Owner Guide Programming Worksheets 10 Protocol 3 Communications Protocol 4 5 IBM Slot Scanner IBM Hand-Held Bar Code Reader RS-232 B D E0 IBM 1520 Bar Code Reader IBM USB NCR (RS-232) USB 20552 7883-1200 only 11 A Tone On/Off Good Read Tone 0 1 Off On B Tone Frequency (Hertz) B When entering Tone Frequency, the adjustment can be incremented upward by scanning the Hex B tag. Each time you scan the Hex B, the tone frequency increases one unit.
NCR RealScan 7883 Installation and Owner Guide 12 8 A Lockout Time (Milliseconds) B Restart Lockout Timer C Active Time (Minutes) Timers 0 1 2 3 900 350 450 600 750 4 5 6 7 1050 1200 1350 1500 0 1 Off On 0 1 2 3 0 15 30 60 NOTE: NCR suggests that you do not set the Active Time parameter to 0. Leaving the laser light on all the time reduces its life expectancy.
NCR RealScan 7883 Installation and Owner Guide 14 A Code 39 B Minimum Characters Allowed C Full ASCII D Check Digit Present E Transmit Check Digit F Allow 1- or 2-Character Tags 54 of 75 Bar Codes - 2 0 1 Disable Enable 2-F Default 0 1 Disable Enable 0 1 Disable Enable 0 1 Disable Enable 0 1 Disable Enable 8 20241-A 04/04 497-0424789 Release F
NCR RealScan 7883 Installation and Owner Guide 15 A Interleaved 2 of 5 B Bar Code Length 0 1 Disable Enable 0 1 Range Check Specific Check Characters Minimum Value 1 0-3 C Check Digit Present D Transmit Check Digit A Code 128 B Minimum Data Characters Allowed C UCC 128 Release F 0 1 Disable Enable 0 1 Disable Enable 0-9 Character 1 Character 2 Default: 0 8 Characters Maximum Value 2 497-0424789 Bar Codes - 3 0-3 0-9 Character 1 Character 2 Default: 1 6 20242-A 17 Bar Co
NCR RealScan 7883 Installation and Owner Guide 18 A RSS Enable Bar Codes – 5 0 1 2 Disable B C D Scans Required On RSS 14 B Identifier Type Common Byte 1 Enable RSS 14 & RSS E 2 3 4 1 Scan 2 Scans 3 Scans 4 Scans 1 2 3 4 1 Scan 2 Scans 3 Scans 4 Scans 0 1 Normal Mode UCC-128 Emulation Mode 16 A Enable RSS E Only 1 Scans Required On RSS E UCC-128 Emulation Mode Enable RSS 14 Only 3 20596 Label Identifiers 0 2 3 Default Prefix None 0-7 0-F Unique Prefix Default 5
NCR RealScan 7883 Installation and Owner Guide 20 A Baud Rate B Parity C Stop Bits And Character Length RS-232 Parameters - 1 0 1 2 3 4 5 6 300 600 1200 2400 4800 9600 19200 0 1 4 Odd Even None 0 1 2 3 1 Stop Bit 7-Bit Character 1 Stop Bit 8-Bit Character 2 Stop Bits 7-Bit Character 2 Stop Bits 8-Bit Character D Handshake 0 1 RTS Low RTS High Ignore CTS Ignore CTS 2 3 4 5 Raise RTS Wait For CTS Raise RTS Ignore CTS RTS Low Wait For CTS RTS High Wait For CTS 20245-
NCR RealScan 7883 Installation and Owner Guide 22 A Prefix Byte RS-232 Prefix Byte 0 1 Disable B ASCII Code Enable 0-7 0-F Hex Character (ASCII Code Chart) Hex Character (ASCII Code Chart) 23 A Terminator Byte Message Delay Normal or Eavesdrop Mode 58 of 75 Default 20247-A RS-232 Terminator Byte 0 1 Disable B ASCII Code 0 2 Enable 0-7 0-F Hex Character (ASCII Code Chart) Hex Character (ASCII Code Chart) 24 0 0 3 Default 20248-A RS-232 Communications Options 1 2 No Delay 10 ms
NCR RealScan 7883 Installation and Owner Guide 32 IBM Tone Control (Good Read Tone Control) Miscellaneous Parameters – RealScan 7883-1000 3 4 Disable Enable 7 8 3 Times Forever E F Hex ASCII IBM Rexmit Control IBM Tag Data Format 20250A 32 Miscellaneous Parameters – RealScan 7883-1200 IBM Tone Control 3 4 (Good Read Tone Control) IBM Rexmit Control Enable/Disable Voice Messages Disable Enable 7 8 3 Times Forever D 3 Times IBM Tag Data Format 497-0424789 Release F 04/04 E F Hex
NCR RealScan 7883 Installation and Owner Guide ASCII Code Chart ASCII Code Chart 00 NULL 10 DLE 20 SP 30 0 40 @ 50 P 60 70 p 01 SOH 11 DC1 21 ! 31 1 41 A 51 Q 61 a 71 q 02 STX 12 DC2 22 " 32 2 42 B 52 R 62 b 72 r 03 ETX 13 DC3 23 # 33 3 43 C 53 S 63 c 73 s 04 EOT 14 DC4 24 $ 34 4 44 D 54 T 64 d 74 t 05 ENQ 15 NAK 25 % 35 5 45 E 55 U 65 e 75 u 06 ACK 16 SYN 26 & 36 6 46 F 56 V 66 f 76 v 07 BEL 17
NCR RealScan 7883 Installation and Owner Guide Regulatory Information Federal Communications Commission (FCC) Radio Frequency Interference Statement Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
NCR RealScan 7883 Installation and Owner Guide Complies with FDA radiation Performance standards 21 CFR Subchapter J. VCCI-1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation.
NCR RealScan 7883 Installation and Owner Guide Declaration of Conformity We, NCR Corporation, Retail Solutions Division Atlanta, 2651 Satellite Boulevard, Duluth, Georgia, 30096-5810, U.S.A., declare under our sole responsibility that the product NCR RealScan 7883 Bar Code Scanner to which this declaration relates is in conformity with the following standard or other normative document following the provisions of the noted Directives.
NCR RealScan 7883 Installation and Owner Guide Laser Safety The NCR RealScan 7883 is not intended for long-term viewing of the direct laser light. However, the unit is safe if used as it was intended. Note: The NCR RealScan 7883 is a CDRH Class IIa and IEC Class 1 Laser Product Laser Safety Label (IEC CLASS 1 LASER PRODUCT) Appareil à Laser de classe IIa Eviter Toute Exposition Prolongeè de la vue à la lumierè laser directe. Producto Laser de Clase IIa.
NCR RealScan 7883 Installation and Owner Guide Laser Power The NCR RealScan 7883 meets the following laser power requirements. • Class 1 EN 60825-1: 1994 (Europäische Norm) • Class 1 IEC 825-1: 1993 (International Electrotechnical Commission) • Class IIA CDRH (Center for Devices and Radiological Health) FDA, U.S.A. Following is the radiant energy of the laser light as applied to each of the specified requirements. Maximum Radiant Power (CDRH Calculation) 2.
NCR RealScan 7883 Installation and Owner Guide Programming Tags Volume Adjustment 11817 Reset 11818 Default R0046 66 of 75 04/04 497-0424789 Release F
NCR RealScan 7883 Installation and Owner Guide Programming Mode R0042 End R0043 Save and Reset R0044 497-0424789 Release F 04/04 67 of 75
NCR RealScan 7883 Installation and Owner Guide Abort R0045 Diagnostic Mode R0041 RS-232 Temporary Service Mode 16576 68 of 75 04/04 497-0424789 Release F
NCR RealScan 7883 Installation and Owner Guide Mode 1 11500 Mode 2 11501 Reset Tallies 11502 497-0424789 Release F 04/04 69 of 75
NCR RealScan 7883 Installation and Owner Guide Firmware Flashing Super ASIC Models 20600 Hex 0 R0048 Hex 1 R0049 70 of 75 04/04 497-0424789 Release F
NCR RealScan 7883 Installation and Owner Guide Hex 2 R0050 Hex 3 R0051 Hex 4 R0052 497-0424789 Release F 04/04 71 of 75
NCR RealScan 7883 Installation and Owner Guide Hex 5 R0053 Hex 6 R0054 Hex 7 R0055 72 of 75 04/04 497-0424789 Release F
NCR RealScan 7883 Installation and Owner Guide Hex 8 R0056 Hex 9 R0057 Hex A R0058 497-0424789 Release F 04/04 73 of 75
NCR RealScan 7883 Installation and Owner Guide Hex B R0059 Hex C R0060 Hex D R0061 74 of 75 04/04 497-0424789 Release F
NCR RealScan 7883 Installation and Owner Guide Hex E R0062 Hex F R0063 Copyright © 2003 by NCR Corporation 497-0424789 Release F 04/04 75 of 75