NCR 7454 Retail Terminal Release 2.
The product described in this book is a licensed product of NCR Corporation. NCR is a registered trademark of NCR Corporation. NCR RealPOS, NCR RealScan, and NCR EasyPoint are either registered trademarks or trademarks of NCR Corporation in the United States and/or other countries. It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available. NCR, therefore, reserves the right to change specifications without prior notice.
7454 Retail Terminal Site Preparation Preface This is a contractual document. It contains important warnings and confers important legal rights and obligations. You are advised to read it carefully. It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with NCR specifications and requirements and all applicable national, state, or local codes, regulations, and laws.
ii 7454 Retail Terminal Site Preparation Lithium Battery Warning Caution: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type as recommended by the manufacturer. The battery is battery is recyclable. At the end of its useful life, under various state and local laws it may be illegal to dispose of this battery into the municipal waste. Contact officials for recycling options or proper disposal.
7454 Retail Terminal Site Preparation iii Environmental Consciousness NCR is demonstrating its concern for the environment by designing an intelligent power management system into this terminal that operates efficiently whether the system is in a stand-alone or network environment. Grounding Instructions In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.
iv 7454 Retail Terminal Site Preparation About this Book This book provides site preparation information for terminal components. Peripheral component and AC wiring site preparation information is NOT provided in this book. The associated reference documents are listed in the "Related Site Preparation Data" section. This book contains the information necessary for the preparation of a site that conforms to NCR specifications.
454 Retail Terminal Site Preparation v No comment, suggestion, or advice offered or not offered about preparation of the site, nor any inspection of the site, whether before of after preparation, is to be taken as approval of the location of the site and equipment or its preparation. NCR will not be liable in respect to any comment, suggestion, or advice given by its staff or in respect to any failure to give advice.
vi 7454 Retail Terminal Site Preparation
7454 Retail Terminal Site Preparation Table of Contents Introduction 1 Interpreting the Model Number..................................... 2 Related Site Preparation Data......................................... 3 Accessing Information Products .................................... 3 Customer Responsibilities 4 AC Store Wiring Requirements 5 LAN Communications 5 System Configuration Diagram 6 Physical Considerations 7 Operating and Service Clearance Requirements...........
viii 7454 Retail Terminal Site Preparation NCR 7167 Thermal Receipt and Impact Slip Printer....................................................................... 16 NCR 7194 Printer..................................................... 17 NCR 7196 Printer..................................................... 17 NCR 7197 Thermal Receipt Printer........................ 18 NCR 2214 Thermal Fiscal Printer........................... 18 NCR 5974 4x20 Remote Customer Display ...........
7454 Retail Terminal Site Preparation Printer Interface Cables (RS-232) ........................... 37 Printer Power Cables .............................................. 38 NCR 5972-1000 Remote Customer Display and Adapter Cables........................................................ 39 External CD-ROM Cable ........................................ 40 Power, AC................................................................ 41 Environmental Requirements 42 Barometric Pressure ..........................
x 7454 Retail Terminal Site Preparation Revision Record Issue Date Remarks A Sep 00 First issue (Release 1.5) B Feb 01 Updated to Release 2.0 Added 2214 printer C Dec 02 Updated to Release 2.
7454 Retail Terminal Site Preparation xi Radio Frequency Interference Statements Federal Communications Commission (FCC) Information to User This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
xii 7454 Retail Terminal Site Preparation Voluntary Control Council for Interference (VCCI) International Radio Frequency Interference Statement This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
7454 Retail Terminal Site Preparation xiii Declaration of Conformity Manufacturer's Name NCR Corporation Manufacturer's Address NCR Corporation Retail Solutions Division – Atlanta 2651 Satellite Boulevard Duluth, GA 30096-5810 Type of Equipment Information Technology Equipment Model Number Class 7454 Electrical Ratings (Input) 100-120 V/200-240 V, 2.0 A/1.
xiv 7454 Retail Terminal Site Preparation
Site Preparation Introduction NCR 7454 18051 This document provides the information necessary to prepare a site to NCR specifications prior to installing a terminal. The site must be properly prepared before the terminal is installed because site preparation deficiencies may be difficult to detect and correct after installation. The terminal consists of separate pieces that may be combined in a variety of configurations. Certain combinations are mutually exclusive.
2 7454 Retail Terminal Site Preparation Interpreting the Model Number NCR Model 7454 22 XX 80 01 Language 01 = International English Power Required 80 = 110 -240 VAC 50/60 Hz Operating System 00 = No OS 01 = Windows 03 = MS/DOS 04 = No meaning Processor Release 1 22 = Base Unit with 12.1" LCD Release 2 32 = 12.1" Summa POS, Celeron 600 MHz (G105) Release 2.2 34 = 12.1" Summa POS, Celeron 700 MHz (G105) 35 = 15" Summa POS, Celeron 700 MHz (CG01) 36 = 12.1" Summa POS, Celeron 700 MHz (CG01) 37 = 12.
7454 Retail Terminal Site Preparation Related Site Preparation Data AC Power and Communications Wiring Title Order Number NCR Ethernet Communications Wiring Guide BST0-2118-82 NCR Terminal AC Power Wiring Guidelines BST0-2115-53 Peripherals Title Order Number NCR 7158 Thermal Receipt/Impact Printer B005-0000-1112 NCR 7161 Thermal Receipt Printer Owner's Guide B005-0000-1067 NCR 7166 Thermal Receipt/Impact Printer B005-0000-1002 NCR 7193 Thermal Receipt Printer Owner's Guide BD20-1439-A NCR
4 7454 Retail Terminal Site Preparation Customer Responsibilities Before the system can be installed, the customer must do or provide the following: • When required by NCR, provide the NCR Customer Services representative with appropriate drawings that indicate: − Location of the equipment − Site wiring (power and communications, paths and lengths) − Location of other equipment that may generate electrical noise, electromagnetic interference, or heat.
7454 Retail Terminal Site Preparation AC Store Wiring Requirements The customer must provide suitable AC power for the retail terminals, associated equipment, and devices. A dedicated unswitched power line dedicated to the NCR equipment installation is recommended. Refer to the Workstation and Peripherals AC Wiring Guide (BSTO2115-53) for store AC wiring requirements. The AC outlet must be installed near the retail terminal and easily accessible to the operator.
6 7454 Retail Terminal Site Preparation System Configuration Diagram 2214 7196 7166 7837 7892 2010 Coin Dispenser 2336-K008 7197 7194 7167 RS232 (4) 2 Optionally Powered 7158 5972/5973 VGA Processor Board USB Note: 7158, 7167, 7194, and 7197 are available in both RS-232 and USB. PS/2 KBD POS Connector Bd.
7454 Retail Terminal Site Preparation Physical Considerations This section presents the following retail terminal information: • Operating and service clearance requirements • Display mounting considerations • Retail terminal and component dimensions • Component weights • Airflow requirements • Power requirements 7
8 7454 Retail Terminal Site Preparation Operating and Service Clearance Requirements Location Component Distance Reason Above 2214 Printer 371 mm (14.6 in.) Clearance to raise printer cover 7158 Printer 305 mm (12 in.) Clearance to raise printer cover 7166 Printer 280 mm (11 in.) Clearance to raise printer cover 7167 Printer 305 mm (12 in.) Clearance to raise printer cover 7194 Printer 228 mm (9 in.
7454 Retail Terminal Site Preparation 9 Component Dimensions NCR 7454 (12.1 Inch) 400 mm (16 in.) 370 mm (14.5 in.) 380 mm (15.0 in.) 360 mm (14.0 in.
10 7454 Retail Terminal Site Preparation NCR 7454 (15 Inch) 425 mm (16.75 in.) 394 mm (15.5 in.) 412 mm (16.25 in.) 35 mm (14.0 in.
7454 Retail Terminal Site Preparation 11 NCR 7454 (12.1 Inch) with PCMCIA 401mm (15.8 in.) 370 mm (14.5 in.) 40.7 mm (1.6 in.) 381 mm (15.0 in.) 312 mm (12.3 in.) 53.4 mm (2.1 in.) 73.7 mm (2.9 in.) 18200 NCR 7454 (15 inch) with PCMCIA 426 mm (16.8 in.) 14.3 mm (0.6 in) 391 mm (15.5 in.) 392 mm (15.4 in.) 338 mm (13.3 in.) 53.4 mm (2.
12 7454 Retail Terminal Site Preparation NCR 7454 (12.1 Inch) w/K450 Integrated Customer Display 400 mm (16 in.) 480 mm (19.0 in.) 366 mm (14.3 in.
7454 Retail Terminal Site Preparation 13 NCR 7454 (15 inch) w/K450 Integrated Customer Display 425 mm (18.75 in.) 394 mm (15.5 in.) 480 mm (19.0 in.) 366 mm (14.3 in.
14 7454 Retail Terminal Site Preparation NCR 2183 Cash Drawer 455 mm (17.9 in.) 114 mm (4.50 in.) 450 mm (17.7 in.) Operating and Service Clearance for Drawer 263 mm (10.4 in.) 18038a NCR 2189 Cash Drawer 464 mm (18.25 in.) 133 mm (5.25 in.) 527 mm (20.5 in.) 330 mm Operating and (13 in.
7454 Retail Terminal Site Preparation 15 NCR 2113 Cash Drawer 400 mm (15.75 in.) 96 mm (3.75 in.) 450 mm (17.75 in.) 254 mm (10 in.) Operating and Service Clearance for Drawer 17310 NCR 7158 Printer 165 mm (6.50 in.) 305 mm (12.00 in.) 336 mm (13.25 in) 229 mm (9.
16 7454 Retail Terminal Site Preparation NCR 7166 Printer 171 mm (6.75 in.) 280 mm (11.00 in.) 330 mm (13.00 in.) 248 mm (9.75 in.) 17308 NCR 7167 Thermal Receipt and Impact Slip Printer Top Cover Open 296 mm (11.7 in.) 174 mm (7.0 in.) 262 mm (10.3 in.) 190 mm (7.5 in.) 316 mm (12.5 in.
7454 Retail Terminal Site Preparation 17 NCR 7194 Printer 212 mm (8.3 in.) 130 mm (5.10 in.) 85 mm (3.30 in.) 157 mm (6.20 in.) 187 mm (7.4 in.) 16492 NCR 7196 Printer 146 mm (5.75 in.) 108 mm (4.25 in.) 254 mm (10.00 in.) 140 m (5.50 in.
18 7454 Retail Terminal Site Preparation NCR 7197 Thermal Receipt Printer Top Cover Open 256 mm (10.1 in.) 156 mm (6.25 in.) 184 mm (7.25 in.) 146 mm (7.75 in.) 19712c NCR 2214 Thermal Fiscal Printer 371 mm (14.6 in.) 175 mm (6.9 in.) 278 mm (11 in.) 210 mm (8.3 in.
7454 Retail Terminal Site Preparation 19 NCR 5974 4x20 Remote Customer Display 180 mm (7 in.) 50 mm (3.5 in.) 110 mm (4.25 in.) 506 mm (22.1 in.) 95 mm (3.75 in.) 95 mm (3.75 in.
20 7454 Retail Terminal Site Preparation NCR 5972-1000 2x20 Remote Customer Display 262 mm (10.3 in.) 30 mm (1.2 in.) 119 mm (4.7 in.) 506 mm (22.1 in.) 95 mm (3.75 in.) 95 mm (3.75 in.
7454 Retail Terminal Site Preparation 21 Integrated 5973 International VFD Customer Display 262 mm (10.3 in.) 45 mm (1.8 in.) 110 mm (4.3 in.) 350 mm (13.8 in.) 95 mm (3.75 in.) 95 mm (3.75 in.
22 7454 Retail Terminal Site Preparation 5973 International VFD Customer Display 262 mm (10.3 in.) 45 mm (1.8 in.) 110 mm (4.3 in.) 556 mm (21.9 in.) 95 mm (3.75 in.) 95 mm (3.75 in.
7454 Retail Terminal Site Preparation 23 Remote 5973 International VFD Customer Display 262 mm (10.3 in.) 110 mm (4.3 in.) 45 mm (1.8 in.) 158 mm (6.2 in.) 178 mm (7.0 in.) 173 mm (6.8 in.
24 7454 Retail Terminal Site Preparation NCR 2336-K007 External CD-ROM Drive 155 mm (6.1 in.) 218 mm (8.6 in.) 23 mm (0.9 in.) 16951 Note: Allow 75 mm (3 in.) clearance in the back of the NCR 2336-K007 External CD-ROM Drive for connector and cable clearance. NCR 2336-K008 USB RS-232 Port Server 183 mm (7.2 in.) 111 mm (4.4 in.) 26 mm (1.0 in.
7454 Retail Terminal Site Preparation Component Weights The following table shows the weight of the 7454 retail terminal components. Retail Terminal Component kg lbs. 2189 Cash Drawer 9.5 20.9 7454-K005 Cash Drawer 11.4 25.15 7454-K453 Remote Customer Display 0.7 1.5 5972-1000 Remote Customer Display 0.7 1.5 7156 Multifunction Printer 4.1 9.1 7158 Receipt/Impact Printer 4.8 10.5 7166 Receipt/Impact Printer 5.6 12.3 7167 Thermal Receipt & Impact Slip Printer 4.
26 7454 Retail Terminal Site Preparation Ventilation Clearance The following illustration shows the minimum clearances for proper cooling. 25 mm (1 in.) 76 mm (3 in.
7454 Retail Terminal Site Preparation 27 Power Requirements Core module contain a three-wire, single-phase, selectable 120/240 volt AC, 85 Watt power supply. The supply powers the retail terminal, scanner, VFD display, keyboard, USB interface, cash drawer, integrated speakers, and PCMCIA cards. The following tables show operating specifications for the power supply. Maximum Input Power Specifications 120 Volt Voltage Ranges Frequency Current (A) Power (W) Power Factor (typical) 90 - 136 VAC 50/60 Hz 2.
28 7454 Retail Terminal Site Preparation 7454 Power Consumption Matrix The following table is provided as a reference of the power consumption of the peripherals available on the 7454 Note: All power data listed in table below is rated in amperage. Item Description 3.3VDC 5.0VDC 4.10 2.00 7.80 3.00 2.70 0.04 Power available for Peripherals 2.10 0.20 4.60 2.66 LCDs: Samsung TFT (006-8603280 or 006-8604312), or Sharp DSTN 006-8601845 MSR Modules 0.
7454 Retail Terminal Site Preparation Item Description 3.3VDC (2336-K008, 497-0413014) USB to 2 port RS-232 (2336-K012, 497-0413710) PCMCIA Controller 5.0VDC 12VDC 29 Requires external power source 0.50 0.40 0.50 IRDA 5992 Signature capture device (497-0417590) 5945 Electronic Payment Device (497-0411818) 7837 Hand held Scanner 7892 Presentation Scanner 7882 Scanner 0.80 0.50 0.30 0.50 0.
30 7454 Retail Terminal Site Preparation Considerations for Enclosed Installations Thermal Test Points With the terminal installed in the enclosure, verify that the temperature o o does not exceed 45 C (115 F) in the operating environment. Thermal test points are shown below: Thermal Test Points (Case over Hard Drive and Processor) 18055a Note: For terminal servicing information refer to NCR 7454 Retail Terminal Hardware Service Guide (B005-0000-1342).
7454 Retail Terminal Site Preparation 31 Flush Wall Mount The 7454 can be mounted flush against a wall. The following shows mounting configuration and brackets: Flush Mount w/Power Supply Mounted on the Outside Wall Flush Mount w/Power Supply Mounted on the Inside Wall 16683 Note: Refer to the Cable Illustrations section for cable pass-through hole sizes.
32 7454 Retail Terminal Site Preparation Power Supply 152 mm (6 in.) 102 mm (4 in.) 57 mm (2.25 in.) 17406 Wall mount the Terminal Bracket Drill a hole in the wall for the cables if you are mounting the power supply on the opposite side of the wall.
7454 Retail Terminal Site Preparation 33 System Cables Cable Type Cable Name Cash Drawer Dual Drawer, Y cable Communications Ethernet, 10/100Base-T NCR Part No. 497-0409394 497-0008623 (Unshielded) USB 497-0415949 USB 497-0415950 Displays Remote Customer Display 497-0405676 (Parallel) Parallel I/F Cable 497-0411000 (adapter cable) Power U.S. – Straight 006-1009037 U.S. – Twist-lock 250-0023191 Intl. – straight 'bm' power 006-8601010 Intl.
34 7454 Retail Terminal Site Preparation Cable Type Cable Name Printer Extender 7161/7166/7196 Drop Cables Printer/Workstation (7453-K641) 7193/7194 Printer Printer Power 7193 Printers Supply 7194 Printer NCR Part No. Corp. ID No. Approximate Cable Length 497-0411815 1416-C417-0040 4 m/13 ft. 497-0411816 497-0405937 1416-C418-0040 1416-C286-0010 4 m/13 ft. 1 m/3.3 ft. 497-0405945 1416-C286-0040 4 m/13 ft.
7454 Retail Terminal Site Preparation 35 Cable Illustrations Dual Cash Drawer, Y-cable Cash DWR. #1 497-0409394 Cash DWR. #2 16 mm (0.625 in.) Access Hole Diameters 51 mm (2.0 in.) 15808 Ethernet, 10/100 Base-T Modular 8-Pin Plug Modular 8-Pin Plug 497-0008623 19 mm (.75 in.) Access Hole Diameters 19 mm (.75 in.
7454 Retail Terminal Site Preparation USB, 1- or 4-Meter 497-0415949 (1 meter) 1416-C528-0010 498-0415950 (4 meter) 1416-C528-0040 2 3 Type B USB Type A USB 1234 4 P2 1 36 P1 Access Hole Diameters 6.4 mm (0.25 in.) 15 mm (0.63 in.
7454 Retail Terminal Site Preparation 37 Printer Interface Cables (RS-232) 7161/7166/7196 9-pin D-shell Receptacle 497-0407427 - 1 m 497-0407429 - 4 m 497-0407430 - 15 m 25-pin D-shell Plug Workstation RS-232 Port Printer 38 mm (1.5 in.) Access Hole Diameters 63.5 mm (2.5 in.) 13224 7193/7194/7158 9-pin D-shell Receptacle 497-0408349 - 0.7 m 497-0407943 - 4 m 497-0409379 - 15 m 9-pin D-shell Receptacle Workstation RS-232 Port Printer 38 mm (1.5 in.) Access Hole Diameters 38 mm (1.5 in.
38 7454 Retail Terminal Site Preparation NCR 7161 Printer with 7454-K641 Cable Extender 9-pin D-shell Receptacle 25-pin D-shell Plug Workstation RS-232 Port 25-pin D-shell Receptacle 7453K641 497-0411815 - 4m 1416-C417-0040 9-pin D-shell Plug 7161 Printer 497-0411815 - 4m 1416-C417-0040 16294 NCR 7193 Printer with 7454-K641 Cable Extender 9-pin D-shell Receptacle 25-pin D-shell Plug Workstation RS-232 Port 497-0411815 - 4m 1416-C417-0040 25-pin D-shell Plug 25-pin D-shell Receptacle 7453K641
7454 Retail Terminal Site Preparation 39 NCR 5972-1000 Remote Customer Display and Adapter Cables Parallel I/F Cable 497-0411000 - 0.6 M To 7454 Cust. Display Port 25-pin D-Shell Receptacle 497-0405676 - 4 M 1416-C278-0040 24-pin Microfit Receptacle To Customer Display 8-pin Microfit Receptacle To Power Brick Access Hole Diameters 57.1 mm (2.25 in.) 19 mm (0.75 in.) 25 mm (1.0 in.
40 7454 Retail Terminal Site Preparation External CD-ROM Cable 25-pin D-Shell Receptacle 497-0413011 - 0.6 M 1416-C464-0006 28-pin Sub-Miniture D-Plug To 7454 Cust. Display Port To CD-ROM Parallel Connector SMK 2 mm Plug To CD-ROM Power Connector Access Hole Diameters 57 mm (2.25 in.) 12 mm (0.5 in.) 31 mm (1.25 in.) 16959 External Parallel Cable 25-pin D-Shell Receptacle 497-0411000-0.6 M 1416-C472-0006 28-pin Sub-Miniture D-Plug To 7454 Cust.
7454 Retail Terminal Site Preparation 41 Automatic Change Dispenser Serial Cable P1 5 9 1 6 P2 497-0404832 9-Pin D-shell Receptacle 25-pin D-shell Plug 1 14 13 25 18056 Power, AC 006-1009037 Workstation Access Hole Diameter 45 mm (1.75 in.
42 7454 Retail Terminal Site Preparation Environmental Requirements Barometric Pressure The 7454 Retail Terminal is designed to operate within the following barometric pressure conditions: • Maximum operating altitude: 3,000 m (9,843 ft.) • Operating range of pressure: 105 kPa to 69 kPa (15.2 lb/in. to 10.0 lb/in.) Temperature The 7454 Retail Terminal is designed to operate over the temperature ranges shown below.
7454 Retail Terminal Site Preparation 43 Humidity The 7454 Retail Terminal is designed to operate within the humidity ranges shown below. Continuous operation must be avoided, however, at or near the humidity limits, or in locations where humidity changes exceed the humidity restrictions. In no case should the 7454 Retail Terminal be subjected to condensation.
44 7454 Retail Terminal Site Preparation
Appendix A: Transient Protection AC Power Line Transient Protection In the process of power distribution, transient electrical energy (including, but not limited to, lightning strikes, intermittent short circuits, and switching transients) can be introduced onto power lines. Such transient energy can be very damaging to electronic hardware, and can also cause data corruption. Under these circumstances, NCR recommends the use of AC power transient suppressors.
A-2 Appendix A: Transient Protection • Be listed by the accepted safety organization for the country involved (UL, CSA, VDE, ETL, and so on) and the installation must conform to local, state, and national electrical codes and regulations. Data Line Transient Protection The nature of the transient phenomenon may extend to the data communication lines connected to this equipment.
Index —2— 2113 Cash Drawer, 15 2183 Cash Drawer, 14 2189 Cash Drawer, 14 2214 Thermal Fiscal P, 18 2336-K007 External CD-ROM Drive, 24 2336-K008 USB RS-232 Port Server, 24 —5— 5972-1000 2x20 Remote Customer Display, 20 5973 International VFD Customer Display, 22 5974 4x20 Remote Customer Display, 19 —7— 7158 Printer, 15 7166 Printer, 16 7167 Thermal Receipt and Impact Slip Printer, 16 7194 Printer, 17 7196 Printer, 17 7454 (12.1 Inch), 9 7454 (12.1 Inch) w/K450 Integrated Customer Display, 12 7454 (12.
—D— Data Line Transient Protection, 2 Dimensions, 9 —O— Operating Clearance Requirements, 8 —P— —E— Environmental Requirements, 42 Barometric Pressure, 42 Humidity, 43 Temperature, 42 —F— Flush Wall Mount, 31 —H— Humidity, 43 Power Requirements, 27 Power Supply, 32 —R— Remote 5973 International VFD Customer Display, 23 —S— Service Clearance Requirements, 8 System Cables, 33 System Configuration Diagram, 6 —I— Integrated 5973 International VFD Customer Display, 21 —M— Model Number, 2 —N— NCR 7197 T
B005-0000-1257 Dec 2002 Printed on recycled paper