2 Chapter 2: Preparing the Installation Site Preparing the Site This chapter provides the following information: • A summary of customer responsibilities prior to installation • Power, grounding, and distribution requirements of the DecisioNet System • DecisioNet System environmental requirements • DecisioNet System component characteristics
-2 Chapter 2: Preparing the Installation Site Customer Responsibilities The customer must do or provide the following: • When required by NCR, provide the NCR customer service representative with appropriate drawings that indicate: • Fixture Plan showing the location of store fixtures • Floor Plan showing the location of all interior walls, ceiling heights, and firewalls • Site wiring diagrams for power and communication • Location of other equipment capable of generating electrical noise, electr
Chapter 2: Preparing the Installation Site 2-3 Power, Grounding and Distribution Requirements Voltage transients, line noise, surges, sags, impulses, and spikes can happen routinely or sporadically. When such phenomena occur, protective devices such as surge protectors may help to ensure proper operation of the equipment. Power Requirements The CBS does not have an internal power supply. It receives DC power from an external power supply that can support up to five CBSs.
2-4 Chapter 2: Preparing the Installation Site Grounding Requirements Because the DecisioNet System connects logic reference ground to safety ground, a noise-free grounding circuit is necessary for good system integrity. Use an isolated ground receptacle, such as a Hubbell IG-5262 or equivalent. Make sure the ground conductor is insulated from conduit and neutral wire, and that it is connected to an insulated terminal strip at the distribution panel.
Chapter 2: Preparing the Installation Site 2-5 The following illustration shows an example of site wiring.
2-6 Chapter 2: Preparing the Installation Site Environmental Requirements DecisioNet components operate across a wide range of environmental conditions as shown in the following tables. Do not install these components in locations where the temperature or humidity may go beyond the limits indicated. Due to lower atmospheric pressure and air rarefaction at high altitudes, the maximum dry bulb temperature for each working range is decreased linearly by a value of 3.3 °C /1,000m (1.8 °F /1,000 ft.
Chapter 2: Preparing the Installation Site 2-7 ESL (Standard Size and Small Size) Operating Transit (1 week maximum) and Storage (3 months maximum) Temperature (Dry bulb) 0°C to 40°C (32°F to 104°F) -30°C to 60°C (-22°F to 140°F) Max. Temp. Change per Hour Relative Humidity 10°C (50°F) 15°C (59°F) 5% to 90% No condensation 5% to 90% No condensation Max. Humidity Change 10% per Hour Barometric Pressure 70 kilo pascals (up to a max. of 3,000 m [9,842 ft.
2-8 Chapter 2: Preparing the Installation Site ESL (Signage) Operating Transit (1 week maximum) and Storage (3 months maximum) Temperature (Dry bulb) 0°C to 40°C (32°F to 104°F) -30°C to 60°C (-22°F to 140°F) Max. Temp. Change per Hour Relative Humidity 10°C (50°F) 15°C (59°F) 5% to 90% No condensation 5% to 90% No condensation Max. Humidity Change 10% per Hour Barometric Pressure 70 kilo pascals (up to a max. of 3,000 m [9,842 ft.
Chapter 2: Preparing the Installation Site Maximum operating temperature C ( F) 45 (113) 40 (104) 35 (95) 30 (86) 25 (77) Altitude 500 (1,640) 1,000 (3,280) 2,000 (6,560) 3,000 (9,840) meters (feet) Health and Safety CBSs meet the following safety and radio frequency interference requirements. • • • • • • • • • • • • • • • • ANSI C95.1-1990 UL 1950 3rd Edition UL 2043 CSA CAN/CSA-22.2 No. 950-93 CE mark per TULV FCC CFR, Title 47, Part 15.
2-10 Chapter 2: Preparing the Installation Site Component Characteristics CBS The CBS weighs 1.13 kg (2.5 lb.). The following illustration shows the dimensions of the CBS. Back 287.3 mm (11.31 in.) .. 38.6 mm (1.52 in.) . Top 140.4 mm (5.53 in.) Front 18827 The CBS does not have ventilation holes, but it does require the service clearances indicated in following table. Direction Distance in mm Distance in inches Top Bottom Right Left Front Back Not applicable 127 101.6 101.6 101.6 101.
Chapter 2: Preparing the Installation Site 2-11 CBS Power Supply The CBS power supply weighs .85 kg (1.88 lb.). The following illustration shows the dimensions of the CBS power supply. 179 mm (7 in.) Back 48.8 mm (1.9 in.) Top 96 mm (3.8 in.) Front 17069 The CBS power supply has rear ventilation holes, so it requires the air flow and service clearances indicated in the following table. Direction Distance in mm Distance in inches Top 50.8 2 Bottom Right Left Front Back 50.8 50.8 50.8 50.8 50.
2-12 Chapter 2: Preparing the Installation Site Antennas Transmit Antenna The transmit antenna has a threaded female standoff and weighs .085 kg (0.19 lb.). The following illustration shows the dimensions of the transmit antenna. 13 mm .5 in. 45 mm 1.75 in. 45 mm 1.75 in. 17100 Receive Antenna The receive antenna has a threaded female standoff and weighs .085 kg (0.19 lb.). The following illustration shows the dimensions of the receive antenna. 13 mm .5 in. 45 mm 1.75 in. 45 mm 1.75 in.
Chapter 2: Preparing the Installation Site 2-13 ESLs ESLs are available in variety of sizes and LCDs. This section describes the physical characteristics of the available ESLs. ESL, Standard Size The 1x8 and 4+8-character standard-size ESLs weigh 0.031 kg (0.068 lb.). Physical dimensions are shown below. Standard-size 1x8 and 4+8-character "freezer" ESLs are available at GCA. They have the same dimensions and weight as non-freezer standard-size ESLs.
2-14 Chapter 2: Preparing the Installation Site ESL, Small Size The 2x5-character small size ESL weighs 0.023 kg (0.05 lb.). Physical dimensions are shown below. 7.5 mm (.29 in.) 35 mm (1.38 in. ) 9.52 mm (.37 in.) 60 mm (2.36 in.) 14.02 mm (.55 in.) 18869 ESL, Small Signage The 1x6-character small signage ESL weighs 0.068 kg (0.15 lb.). Physical dimensions are shown below. 14.1 mm (.56 in.) 58.3 mm (2.3 in.) 45 mm (1.7 in.) 160 mm (6.3 in.
Chapter 2: Preparing the Installation Site 2-15 ESL, Large Signage The 2x6-character large signage ESL weighs 0.16 kg (0.36 lb.). Physical dimensions are shown below. 12.5 mm (.49 in.) 58.2 mm (2.3 in.) 84.5 mm (3.33 in.) 216 mm (8.5 in.) 18870 ESL Displays and Symbols The ESL displays are shown in the following illustrations. The symbols on the displays are explained in the table following the illustrations.
2-16 Chapter 2: Preparing the Installation Site 4+8-Character, Standard Size PROMO kg 18872 2x5-Character, Small Size SALE ENDS kg 18873 1x6-Character, Small Signage SALE kg ENDS 18874
Chapter 2: Preparing the Installation Site 2-17 2x6-Character, Large Signage PROMO SALE ENDS UNIT PRICE kg 18875 ● Lights when the ESL is out of synchronization for RF communication Lights when the battery is low Customer defined symbol (Accessible from the Promotions option in ESL Maintenance or from a custom application) UNIT Customer defined symbol PRICE Customer defined symbol SALE Customer defined symbol ENDS Customer defined symbol PROMO Customer defined symbol Cents currency symbol Eu
2-18 Chapter 2: Preparing the Installation Site For ESL configuration information refer to the DecisioNet User's Guide (B005-0000-1317).