User's Manual

D-20 Customizing the DecisioNet System
Unconfigured CBS detect good communication link error message indicates that a
CBS was improperly configured or the BASESW.CFG file was modified incorrectly.
Stop and restart the CBS Manager to correct the problem.
Power supply error message may indicate that a power supply is turned off or
that a power cable integrity problem exists. The error may also occur when too
many CBSs are attached to the power supply.
Receive antenna A off error message identifies a problem with receive antenna A
or CBS receive antenna A port. The error may also occur when receive antenna A
is improperly configured using ESADMIN.
Unconfigured receive antenna B error message indicates a hardware configuration
problem. Use the ESADMIN base config menu option to configure antenna B.
Noise level threshold error message indicates a CBS Manager thresholding
problem. Ambient noise in the environment is causing EPL communication
problems. Call your NCR Field Engineer immediately.
Signal level threshold error message indicates a CBS Manager thresholding
problem. Ambient noise in the environment is causing EPL communication
problems. Call your NCR Field Engineer immediately.
Detail
Date Time Source Description
-------------------------------------------------------------------------------
02/16/98 15:03:37 ESPRCVRF Function call es_open_plu called from open_prcvrf
failed. rc = -1108(Unable to establish IPC connection.)
02/16/98 15:16:16 ESFDA Connection status is down for CBS 3
02/16/98 15:17:26 ESFDA Comm link is not established for CBS 3
02/16/98 15:17:42 ESFDA RF power is off for CBS 2
02/16/98 15:21:44 ESFDA RS-485 cable fault detected at CBS 3
02/16/98 15:21:45 ESFDA RF power is off for CBS 2
02/16/98 15:32:05 ESFDA Master CBS link is down
02/16/98 15:38:02 ESFDA EPL communication is closed
02/16/98 15:43:25 ESFDA Unconfigured CBS 2 detected good comm link
02/16/98 15:48:43 ESFDA Unable to open configuration file
02/16/98 16:08:31 ESFDA Power supply B failure detected
02/16/98 16:18:54 ESFDA Receive antenna A failure for CBS 0
02/16/98 16:18:54 ESFDA Unconfigured receive antenna B for CBS 0
02/16/98 16:24:56 ESFDA Noise level threshold for CBS 0 is too high (65)
02/16/98 16:24:56 ESFDA Signal level threshold for CBS 0 is too high (67)
02/16/98 16:36:08 ESFDA EPL battery low error (quantity: 2 of 3)
02/16/98 16:37:08 ESFDA EPL hardware error (quantity: 2 of 3)
02/16/98 16:38:08 ESFDA EPL does not respond to existence bedcheck (quantity:
2of3)