User's Manual
C-18 Configuration Files
is running or not."
2103, "Unable to communicate with the EPL Table Manager. Check to see if the EPl
Table Manager is running."
2500, "Promo Mismatch. (Meaning-A promotion change has been made to an item
linked to an EPL but the change was not detected by the EPL system. This can be
caused if EXTDI is not running or is running less frequently that the Promo
Message Verifier)."
2701, "Communication link not established error message indicates that the CBS is
not responding. Check CBS power and cables. Replace the CBS if the problem
persists.
2702, "Unconfigured CBS detect good communication link error message indicates
that a CBS was improperly configured or the BASESW.CFG file was modified
incorrectly. Stop and restart the CBS Manager to correct the problem.
2703, "Master clock absent error message indicates a RS-485 cable integrity
problem or an internal CBS problem. If all CBSs indicate this error, the master
CBS may be responsible. Power cycle the CBS. If the problem persists, replace
the CBS.
2704, "RF power off error message indicates a problem with the CBS's RF board.
If problem persists, replace the CBS.
2705, "Unconfigured CBS detected RF power on error message indicates that the CBS
is transmitting, but has not been configured and enabled through the ESADMIN base
config menu.
2708, "Diagnostic error message indicates that level 0 diagnostic errors have
occurred. Use ESADMIN to reset the diagnostic test status, then re-examine. If
the problem persists, replace the CBS.
2709, "Unable to poll error message indicates that too many CBSs are connected.
Remove a CBS from the link or disable it using the ESADMIN base config menu.
2710, "Connection status down error message indicates that the CBS Manager does
not know that the CBS is configured. Stop and restart the CBS Manager to correct
this problem.
2711, "RS-485 cable error message indicates a cable integrity problem. Ensure
that there are no cable breaks and that the cable is properly attached.
2712, "Power supply error message may indicate that a power supply is turned off
or that a power cable integrity problem exists. The error may also occur when
too many CBSs are attached to the power supply.
2713, "Receive antenna A off error message identifies a problem with receive
antenna A or CBS receive antenna A port. The error may also occur when receive
antenna A is improperly configured using ESADMIN.
2714, "Unconfigured receive antenna A error message indicates a hardware
configuration problem. Use the ESADMIN base config menu option to configure
antenna A.
2715, "Receive antenna B off error message identifies a problem with receive
antenna B or CBS receive antenna B port. The error may also occur when receive
antenna B is improperly configured using ESADMIN.
2716, "Unconfigured receive antenna B error message indicates a hardware
configuration problem. Use the ESADMIN base config menu option to configure
antenna B.
2717, "Receive antenna C off error message identifies a problem with receive
antenna C or CBS receive antenna C port. The error may also occur when receive
antenna C is improperly configured using ESADMIN.
2718, "Unconfigured receive antenna C error message indicates a hardware