User Manual
Stift eindrücken
und Akku herausschieben
Page 1
%
%
%
%
Portable transmitter with two replaceable 7,2 volt NiCd batteries, neck and waist
straps.
Receiver with NBB adapter plate for fastening purposes (PNN-BUS-3), receiver with 4
fixing angles (PNN-BUS-5), with 1 mounting bracket (PNN-R-10) or with integrated
mounting holes (PNN-R-6, -16, -CAN and PNN-Compact).
Multi-pin connecting cable for the receiver according to your specifications.
Automatic battery charger with charging adapter (rapid charging in three hours).
For explanatory notes on obtaining an operating permit please refer to registration docu-
ments enclosed in the appendix of this operating instruction. Observe all applicable work-
safety and accident prevention regulations carefully. Only fully trained, authorized per-
sonnel may use the NBB radio control equipment. Components, etc. built into the NBB
equipment for safety purposes must be regularly inspected.
Failure to observe these recommendations will put both you yourself and others at risk.
Under these circumstances, NBB rescinds the guarantee and any other form of liability.
This radio control unit is designed exclusively for the control of construction machines
and industrial plants. Only under these conditions are the safety systems (EMERGENCY
STOP, zerosetting) fully effective. No other form of use is permitted.
Any non-observance of this condition will relieve NBB of all liability.
To make the unit ready fo r use, ins er t the battery into the battery compar tmen t. To remo-
ve the battery, press in the pin and push out the battery. The power supply to the transmit-
ter is activated with the EMERGENCY STOP switch. (When pressed, the EMERGENCY
STOP switch can also be secured by removing the key cap). The green LED on the trans-
mitter control panel must flash regularly. Commands can now be put in by means of the
controls. The operating period with a charged battery is approximately 8 hours with the
transmitterincontinuous use.
When the red "Battery" indicator lamp lights up, the battery is nearly empty. The transmit-
ter can be operated for approximately 15 minutes more in this condition. Duringthis time,
bring the unit to be controlled to a safe position and install a new battery. Removal of the
battery interrupts the radio link. As a result, the master switch for the unit to be controlled
must beswitchedonagain. Chargethedischargedbattery withthecharger supplied.
The actual delivery specification is as detailed on the confirmation of order or
the delivery note accompanyingthe goods!
Even if you are accustomed to working with radio control systems, read these
operating instructions carefully before using this equipment. Only this docu-
ment contains the latest information relating to your NBB radio control system.
If the NBB radio control unit develops a fault, it must be shut down immediately.
The transmitter should be switched off with the EMERGENCY STOP switch. The
connecting cable must be disconnected at the receiver from the connecting so-
cket (terminal) of the unit to be controlled . The repair of the equipment must not
be carried out other than by NBB or an NBB authorized technician.
3. TRANSMITTER Nano-L
Nano-L-A2/1 Nano-L-A2/2 Nano-L-A2/2 Nano-L-A2/3 Nano-L-A1/6
START
2. SAFETY PRECAUTIONS
1. STANDARD SPECIFICATION