Transmitter PocketEvo
®
Operation of the system
> Switching the transmitter on and off
CDC-key (Customer Data Collection)
The transmitter can only be started with the CDC-key inserted.
If the CDC-key is not present, the display changesbetween “no” and “tA”.
CDC-key contains customer-specific parameters.
Design with emergency stop
Unlock the emergency stop pushbutton by turning clockwise to switch on the transmitter.
The transmitter vibrates shortly.
In operation two red dots flash alternately in the display.
Switch off the transmitter by pressing the emergency stop pushbutton once.
After pressing the emergency stop pushbutton, the transmitter sends stop telegrams for 2 seconds
to switch off the system. This shut-off time is displayed on the LED display by the external segments
rotating clockwise.
To ensure faultless free operation, please observe the following rules:
The system to be controlled – provided the transmitter is ready for operation – can only be switched on
if no command is activated. To start the system to be controlled and to activate the functions press the
“On/Horn” button, which also triggers a horn signal. Due to work specifications, the same button is
used for triggering repeated horn signals.
> Frequency change
To change the frequency, press and hold the left side button “On/Horn”. Press now the right side
button “frequency change”. If the receiver locks on a new frequency, a horn signal is triggered and
the system is ready for operation. Please observe the country-specific regulations.
Operation: Two red dots flash
alternately.
1. On/Horn
2. Frequency change