User Manual
1 2 3 4
www.nbb.de
®
COMPACT-V
X
3.820.1195
LEDS
COMPACT-M
R-16
R-CAN
SERVICE PLUGLED RADIO ON
LED RADIO ON SERVICE PLUG
SERVICE PLUG
To maintain operational safety, a regular function check of the NBB radio remote control is
necessary. In single-shift day-to-day operation, we recommend performing this check at
least once a week. Checking is possible using the display lights provided on the receiver.
To do so, the transmitter must be set to the ready-to-operate state.
First connect just the receiver - the transmitter remains switched off.
Activate the transmitter by unlocking the EMERGENCY STOP switch, resp. pres-
sing the key "START/ON/HORN".
Now check the commands (always start with the lowest stage) and check for cor-
rect reaction of the unit to be controlled.
Ensure in particular that there is nobody in the danger area.
, resp. . Press the EMERGENCY STOP switch at
the transmitter until the switch engages, resp. press the STOP key. Then observe
if the unit to be controlled is switched off (time to switch off according to the appli-
cation).
(Optional with integrated charger)
RADIO PRESENT.
If the LED fails to come on:
1. Check that the transmitter is on.
2. Check the power supply of the receiver.
3. (Optional) Irregular flashing of the LED:
Check or change the current radio channel.
(Without integrated charger)
RADIO PRESENT.
If the LED fails to come on:
1. Check that the transmitter is on.
2. Check the power supply of the receiver.
3. (Optional) Irregular flashing of the LED:
Check or change the current radio channel.
%
%
%
%
%
ACCIDENT RISK!
STOP EMERGENCY STOP check
Checking the LED display at the receiver R-16 and R-CAN:
The green LED flashes:
Checking the LED display at the receiver Compact-M:
The green LED flashes:
Service plug: For NBB service only.
Checking the LED's at the receiver Compact-V:
LED 1 green:
LED 2 yellow:
LED 3 green:
LED 4 red:
%
%
%
%
POWER ON. If LED fails to come on, check the power supply.
If the power lead is OK, call in the after-sales service.
HF PRESENT. Steady light when transmitter is switched on
(insignificant for scanner operation).
Flashes evenly during fault-free operation.
Irregular flashing means that the HF channel is probably at
fault - please set another channel.
If this LED flashes, the HF channel is at fault (not in the
scanner operation).
Steady light notifies the operator that an output function
is critical due to over current.
6. FUNCTION CHECK
Page 5