User's Manual

12 | Wiring the radar system
Connect interconection cable to the scanner
The scanner interconnection cable connects the scanner to the RI-10 or RI-11 interface box (or
Lowrance HDS U.S only). The cable connects to the scanner using a 14 pin connector.
Insert cable connector on to the male 14 pin plug on the scanner. take care to align the
connector correctly to avoid bending the pins. Secure the locking collar by rotating clockwise
Feed and secure the cable into the cable retention channel
Interconnection cable pin out
Pinout
Conn Wire color RJ45
1 Black Tinned wire
2 Red Tinned wire
3 Yellow Tinned wire
4 Drain Tinned wire
5 N/A N/A
6 Blue RJ45 Pin 4
7 White / Blue RJ45 Pin 5
8 white / Brown RJ45 Pin 7
9 Brown RJ45 Pin 8
10 White / Green RJ45 Pin 3
11 N/A N/A
12 White / Orange RJ45 Pin 1
13 Green RJ45 Pin 6
Scanner connector
Cable connector
14 Orange RJ45 Pin 2
Connect the interconnection cable to radar interface box
Remove the 4 phillips screws that secure the cable gland housing and disassemble
slide the lock nut, gland washer, and glad housing on to the scanner cable
connect power wires to the terminal strip
connect the RJ45 data connector
secure the gland housing to the interface box using the 4 screws
Insert the gland washer into the gland housing
4 Wirin
g
the radar system
Preliminary