10 | Install the radar
Mounting the scanner
Use the supplied mounting template and tape it securely to the chosen location site.
Before drilling, check that:
-
you have oriented the mounting template correctly so that the front of the scanner
unit will face the front of the vessel
-
the location site is not more than 15 mm (0.6") thick. If the location site is thicker use
longer bolts
Note: The bolts supplied are M8 x 30 mm x 4. If you need to use longer bolts make sure they
are 304 stainless steel and allow for 15 mm (0.6") of thread contact
the location site allows the drain hole to empty.
Drill the four holes where shown.
Remove the mounting template,
Connect the scanner interconnection
cable (see "Connect the Broadband radar to your
display" page 16)
Position the scanner carefully over the bolt holes so that they are aligned
Place a spring washer then a plain washer onto each bolt, as shown.
Screw each bolt into each drill hole from the under side of the location site, and tighten
securely