Operation Manual

15
think safe
USER MANUAL ELECTRONIC LOCK BASIC
3.3 Deleting the time delay
The time delay can only be deleted within the opening window.
1.
Enter your 6-digit code e.g. master code 567891
567891
2.
Wait until the end of the time delay
3.
Opening window starts
4.
Press and hold the key ‘9’ until the red LEDs flash permanently
9
5.
Enter your 6-digit master code e.g. 567891
567891
6.
Delete the time delay
00
7.
Delete the opening window
01
8.
Delete the time delay and opening window again
0001
Step Action Key
4.0 Power supply
4.1 Battery change
Thelockispowersuppliedbyone9Vblockbatteryalkaline(norechargeablebatteries!).Whenbattery
voltage is insufficient, after entering the code a warning tone occurs repeatedly and the red LEDs flash
alternately.
Change the battery as quickly as possible. The programmed codes stay valid during battery change.
To change batteries, open the keypad.
Always dispose used batteries in an environmentally friendly way.
Do you have questions about your safe, the electronic lock or is there an unexpected malfunction?
Please contact your local dealer.