User's Manual
Chapter 2 Function Reference — Lab_ISCAN_Start
©
 National Instruments Corporation 2-273 NI-DAQ FRM for PC Compatibles
For the Lab and 1200 Series devices, if you enable pretrigger mode, Lab_ISCAN_Start 
initiates a cyclical acquisition that continually fills the buffer with data, wrapping around to 
the start of the buffer once NI-DAQ has written to the entire buffer. When you apply the signal 
at the stop trigger input, 
Lab_ISCAN_Start acquires an additional number of samples 
specified by the ptsAfterStoptrig parameter in 
DAQ_StopTrigger_Config and then 
terminates.
Because the trigger can occur at any point in the scan sequence, the scanning operation can 
end in the middle of a scan sequence. See the description for 
Lab_ISCAN_Check to 
determine how NI-DAQ rearranges the buffer after the acquisition ends. When you enable 
pretrigger mode, the length of the buffer, which is greater than or equal to count, should be 
an integral multiple of numChans. 
If you have selected external start triggering of the data acquisition operation, a low-to-high 
edge at the EXTTRIG of the Lab and 1200 Series device I/O connector input initiates the data 
acquisition operation after the 
Lab_ISCAN_Start call is complete. Otherwise, 
Lab_ISCAN_Start issues a software trigger to initiate the data acquisition operation before 
returning.
Note If your application calls Lab_ISCAN_Start, always make sure that you call 
DAQ_Clear before your application terminates and returns control to the 
operating system. Unless you make this call (either directly, or indirectly through 
Lab_ISCAN_Check or DAQ_DB_Transfer), unpredictable behavior might result.