- PXI NI PXI-1056 User Manual
Chapter 2 Installation and Configuration
© National Instruments Corporation 2-13 NI PXI-1056 User Manual
Request for All Status
Note Voltage units are in V
DC
, and temperature units are in degrees Celsius.
Command Response Description
SA <CR><LF>MONITOR,
209-2xxx-Cxx-00 Rx
<CR><LF><CR><LF>
Header information
SP:PS: x <CR><LF> Power supply status, x = OK or FAIL
ST:T1: x <CR><LF> Temperature sensor #1, x = OK or FAIL
ST:T2: x <CR><LF> Temperature sensor #2, x = OK or FAIL
ST:T3: x <CR><LF> Temperature sensor #3, x = OK or FAIL
SV:V1: x<CR><LF> +3.3VDC supply, x = OK or FAIL
SV:V2: x<CR><LF> +5VDC supply, x = OK or FAIL
SV:V3: x<CR><LF> +12VDC supply, x = OK or FAIL
SV:V4: x<CR><LF> –12VCDC supply, x = OK or FAIL
SV:V5: x<CR><LF> +5VDC VSB supply, x = OK or FAIL
SF:F1: x<CR><LF> Fan #1, x = OK or FAIL
SF:F2: x<CR><LF> Fan #2, x = OK or FAIL
SF:F3: x<CR><LF> Fan #3, x = OK or FAIL
SF:F4: x<CR><LF> Fan #4, x = OK or FAIL