- NI 6013/6014 User Manual

Glossary
© National Instruments Corporation G-7 NI 6013/6014 User Manual
library a file containing compiled object modules, each comprised of one of more
functions, that can be linked to other object modules that make use of these
functions.
NIDAQMSC.LIB
is a library that contains NI-DAQ functions.
The NI-DAQ function set is broken down into object modules so that only
the object modules that are relevant to your application are linked in, while
those object modules that are not relevant are not linked.
linearity the adherence of device response to the equation R =KS,where
R = response, S = stimulus, and K = a constant
LSB least significant bit
M
MITE MXI Interface to Everythinga custom ASIC designed by NI that
implements the PCI bus interface. The MITE supports bus mastering
for high-speed data transfers over the PCI bus.
MSB mostsignificantbit
mux multiplexera switching device with multiple inputs that sequentially
connects each of its inputs to its output, typically at high speeds, in order
to measure several signals with a single AI channel
N
NI National Instruments
NI-DAQ National Instruments driver software for DAQ hardware
noise an undesirable electrical signalnoise comes from external sources such
as the AC power line, motors, generators, transformers, fluorescent lights,
soldering irons, CRT displays, computers, electrical storms, welders, radio
transmitters, and internal sources such as semiconductors, resistors, and
capacitors. Noise corrupts signals you are trying to send or receive.
NRSE nonreferenced single-ended modeall measurements are made with
respect to a common (NRSE) measurement system reference, but the
voltage at this reference can vary with respect to the measurement system
ground.