- NI 6013/6014 User Manual
Chapter 4 Connecting Signals
NI 6013/6014 User Manual 4-6 ni.com
Analog Input Signal Overview
The AI signals for the NI 6013/6014 are ACH<0..15>, AISENSE, and
AIGND. Connection of these AI signals to the device depends on the type
of input signal source and the configuration of the AI channels you are
using. This section provides an overview of the different types of signal
sources and AI configuration modes. More specific signal connection
informationisprovidedintheConnecting Analog Input Signals section.
DIO<0..7> DIO — V
CC
+0.5 10 at (V
CC
–0.4) 24 at
0.4
1.1 1.5 kΩ pd
SCANCLK DO — — 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
EXTSTROBE* DO — — 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
PFI0/TRIG1 DIO — V
CC
+0.5 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
PFI1/TRIG2 DIO — V
CC
+0.5 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
PFI2/CONVERT* DIO — V
CC
+0.5 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
PFI3/GPCTR1_SOURCE DIO — V
CC
+0.5 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
PFI4/GPCTR1_GATE DIO — V
CC
+0.5 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
GPCTR1_OUT DO — — 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
PFI5/UPDATE* DIO — V
CC
+0.5 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
PFI6/WFTRIG DIO — V
CC
+0.5 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
PFI7/STARTSCAN DIO — V
CC
+0.5 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
PFI8/GPCTR0_SOURCE DIO — V
CC
+0.5 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
PFI9/GPCTR0_GATE DIO — V
CC
+0.5 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
GPCTR0_OUT DO — — 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
FREQ_OUT DO — — 3.5 at (V
CC
–0.4) 5at0.4 1.5 50 kΩ pu
pd = pull down
pu = pull up
DO = Digital Output
The tolerance on the 50 kΩ pull-up resistors is very large. Actual value may range between 17 and 100 kΩ.
Table 4-3. I/O Signal Summary for the NI 6013/6014 (Continued)
Signal Name
Signal
Type and
Direction
Impedance
Input/
Output
Protection
(Volts)
On/Off
Source
(mA at V)
Sink
(mA
at V)
Rise
Time
(ns)
Bias