Deterministic Ethernet Expansion Chassis User's Guide

NI 9144 User Guide and Specifications 16 ni.com
Shock and Vibration
To meet these specifications, you must panel mount the EtherCAT system
and affix ferrules to the ends of the power terminal wires.
Operating shock (IEC 60068-2-27) ........30 g, 11 ms half sine,
50 g, 3 ms half sine,
18 shocks at 6 orientations
Operating vibration,
random (IEC 60068-2-64) ......................5 g
rms
, 10 to 500 Hz
Operating vibration,
sinusoidal (IEC 60068-2-6) ....................5 g, 10 to 500 Hz
Cabling
Table 2 shows the standard Ethernet cable wiring connections.
Table 2. Ethernet Cable Wiring Connections
Pin Connector 1 Connector 2
1 white/orange white/orange
2 orange orange
3 white/green white/green
4 blue blue
5 white/blue white/blue
6 green green
7 white/brown white/brown
8 brown brown