Network Card User Manual

Chapter 4 Connecting Signals
© National Instruments Corporation 4-19 AT E Series User Manual
Figure 4-5. Summary of Analog Input Connections
+
+
V
1
ACH
AISENSE
AIGND
+
+
V
1
ACH
AISENSE
AIGND
R
See text for information on bias resistors.
+
+
V
1
ACH
AIGND
+
+
V
1
ACH
+V
g
AIGND
Ground-loop losses, V
g
, are added to
measured signal.
NOT RECOMMENDED
+
+
V
1
ACH(+)
ACH()
AIGND
+
+
V
1
ACH(+)
ACH()
AIGND
R
See text for information on bias resistors.
Signal Source Type
Floating Signal Source
(Not Connected to Building Ground)
Grounded Signal Source
Examples
Ungrounded Thermocouples
Signal Conditioning with
Isolated Outputs
Battery Devices
Examples
Plug-in Instruments with
Nonisolated Outputs
Input
Differential
(DIFF)
Single-Ended
Ground
Referenced
(RSE)
Single-Ended
Nonreferenced
(NRSE)