Network Card User Manual

Chapter 4 Connecting Signals
© National Instruments Corporation 4-13 AT E Series User Manual
PFI6/WFTRIG DIO V
cc
+0.5 3.5 at
(V
cc
0.4)
5at0.4 1.5 50 kpu
PFI7/STARTSCAN DIO V
cc
+0.5 3.5 at
(V
cc
0.4)
5at0.4 1.5 50 kpu
PFI8/GPCTR0_SOURCE DIO V
cc
+0.5 3.5 at
(V
cc
0.4)
5at0.4 1.5 50 kpu
PFI9/GPCTR0_GATE DIO V
cc
+0.5 3.5 at
(V
cc
0.4)
5at0.4 1.5 50 kpu
GPCTR0_OUT DO 3.5 at
(V
cc
0.4)
5at0.4 1.5 50 kpu
FREQ_OUT DO 3.5 at
(V
cc
0.4)
5at0.4 1.5 50 kpu
AI = Analog Input DIO = Digital Input/Output pu = pull up
AO = Analog Output DO = Digital Output
The tolerance on the 50 k pull-up and pull-down resistors is very large. Actual value may range between 17 k and 100 k.
Table 4-6. I/O Signal Summary for the AT-MIO-16XE-50
Signal Name Drive
Impedance
Input/
Output
Protection
(Volts)
On/Off
Source
(mA at V)
Sink
(mA at V)
Rise
Time
(ns)
Bias
ACH<0..15> AI 20 Gin
parallel with
100 pF
25/15 ±3 nA
AISENSE AI 20 Gin
parallel with
100 pF
25/15 ±3 nA
AIGND AO
DAC0OUT AO 0.1 Short-circuit
to ground
5at10 5at10 2
V/µs
DAC1OUT AO 0.1 Short-circuit
to ground
5at10 5at10 2
V/µs
AOGND AO
DGND DO
Table 4-5. I/O Signal Summary for the AT-MIO-16XE-10 and AT-AI-16XE-10 (Continued)
Signal Name Drive
Impedance
Input/
Output
Protection
(Volts)
On/Off
Source
(mA at V)
Sink
(mA at V)
Rise
Time
(ns)
Bias