Network Card User Manual
Appendix A Specifications for AT-MIO-16E-1, AT-MIO-16E-2, and AT-MIO-64E-3
AT E Series User Manual A-4 ni.com
Dynamic Characteristics
Bandwidth
Settling time for full-scale step
Small
Signal (–3dB)
Large Signal
(1% THD)
AT-MIO-16E-1 1.6 MHz 1MHz
AT-MIO-16E-2,
AT-MIO-64E-3
1MHz 300 kHz
Gain
Accuracy*
±0.012%
(±0.5 LSB)
±0.024%
(±1 LSB)
±0.098%
(±4 LSB)
AT-MIO-16E-1 0.5 2µstyp
3µsmax
1.5 µs typ
2µsmax
1.5 µs typ
2µsmax
1 2µstyp
3µsmax
1.5 µs typ
2µsmax
1.3 µs typ
1.5 µs max
2to50 2µstyp
3µsmax
1.5 µs typ
2µsmax
0.9 µs typ
1µsmax
100 2µstyp
3µsmax
1.5 µs typ
2µsmax
1µstyp
1.5 µs max
AT-MIO-16E-2 All 2µstyp
4µsmax
1.9 µs typ
2µsmax
1.8 µs typ
2µsmax
AT-MIO-64E-3 All 3µstyp
5µsmax
2µstyp
3µsmax
1.8 µs typ
2µsmax
* Accuracy values valid for source impedances < 1 kΩ. Refer to the Multiple-Channel
Scanning Considerations section of Chapter 3, Hardware Overview, for more information.