Welding System User Manual
Appendix A Status Codes
NI-DAQ FRM for PC Compatibles A-18
©
 National Instruments Corporation
–10688 noTrigEnabledError The number of total scans and pretrigger 
scans implies that a triggered start is 
intended, but triggering is not enabled.
–10689 digitalTrigBError Digital trigger B is illegal for the 
number of total scans and pretrigger 
scans specified.
–10690 digitalTrigAandBError This board does not allow digital 
triggers A and B to be enabled at the 
same time.
–10691 extConvRestrictionError This board does not allow an external 
sample clock with an external scan 
clock, start trigger, or stop trigger.
–10692 chanClockDisabledError The acquisition cannot be started 
because the channel clock is disabled.
–10693 extScanClockError You cannot use an external scan clock 
when doing a single scan of a single 
channel.
–10694 unsafeSamplingFreqError The sample frequency exceeds the safe 
maximum rate for the hardware, gains, 
and filters used.
–10695 DMAnotAllowedError You have set up an operation that 
requires the use of interrupts. DMA is 
not allowed. For example, some DAQ 
events, such as messaging and 
LabVIEW occurrences, require 
interrupts.
–10696 multiRateModeError Multi-rate scanning cannot be used with 
the AMUX-64, SCXI, or pretriggered 
acquisitions.
–10697 rateNotSupportedError Unable to convert your 
timebase/interval pair to match the 
actual hardware capabilities of this 
board.
Table A-1. 
Status Code Summary (Continued)
Status Code Status Name Description