Welding System User Manual
Chapter 2 Function Reference — AI_Change_Parameter
NI-DAQ FRM for PC Compatibles 2-2
©
 National Instruments Corporation
• Pascal programmers—NIDAQCNS.PAS
Legal values for channel depend on the type of device you are using; analog input channels 
are labeled 0 through n – 1, where n is the number of analog input channels on your device. 
You can set channel to –1 to indicate that you want the same parameter selection for all 
channels.
Note For the 611X devices, specify 
ND_PFI_0
 for channel when setting coupling of 
the PFI_0 line for the analog trigger.
Legal values for paramValue depend on paramID. The following paragraph list features 
you can configure along with legal values for paramID with explanations and corresponding 
legal values for paramValue. 
Channel Coupling
Some analog input devices have programmable AC/DC coupling for the analog input 
channels. To change the coupling parameter, set paramID to 
ND_AI_COUPLING. 
Coupling Parameters 
Using This Function
You can customize the behavior of the analog input section of your device by using this 
function. Call this function before calling NI-DAQ functions that cause input on the analog 
input channels. You can call this function as often as needed.
Device Type
Per Channel 
Selection 
Possible
Legal Range for 
paramValue
Default Setting
PCI-6110E Yes ND_AC and ND_DC
ND_DC
PCI-6111E Yes ND_AC and ND_DC
ND_DC
PCI-445X Yes ND_AC and ND_DC
ND_AC
PCI-455X Yes ND_AC and
ND_DC
ND_AC