Welding System User Manual
Chapter 2 Function Reference — GPCTR_Change_Parameter
©
 National Instruments Corporation 2-201 NI-DAQ FRM for PC Compatibles
paramID = ND_START_TRIGGER (6602 and 455X devices only)
This 
paramID
 allows you to change how a counter arms itself. If 
paramValue
 is set to 
ND_ENABLED
, the counter will be armed using a hardware arm. If 
paramValue
 is set to 
ND_DISABLED
, the counter will be armed using a software arm. 
ND_DISABLED
 is the default 
value.
You can synchronize the arming of multiple counters using a hardware signal. Counters must 
be previously software armed before the hardware arm takes place. The hardware arming 
circuitry looks for a rising edge on the hardware arming pin.
paramID = 
ND_SOURCE_POLARITY
The general-purpose counter counts these the transitions of this the signal selected by 
paramID
=
ND_SOURCE. ND_SOURCE
. Corresponding legal values for 
paramValue
 are 
as follows:
•
ND_LOW_TO_HIGH
—counter counts the low-to-high transitions of the source signal
•
ND_HIGH_TO_LOW
—counter counts the high-to-low transitions of the source signal
paramID =
ND_PRESCALE_VALUE
(
6602 and 455
X
 devices only)
This 
paramID
 specifies a prescaling to the counter source selection. Using this 
paramID
allows the counter to measure frequencies higher than the normal counter-timer maximum. 
Corresponding legal values for 
paramValue
 are as follows:
•
ND_ONE
—use this value if no prescaling is needed
•
ND_MAX_PRESCALE
—measures signals of a frequency that is an order of 
ND_MAX_PRESCALE
 higher than the maximum frequency supported by the 6602 and 
455
X
 counter-timers. The value of 
ND_MAX_PRESCALE
 can be queried using the 
GPCTR_Watch
function call
paramID 
= 
ND_INPUT_CONDITIONING
 (
6602 and 455
X
 devices only)
The general-purpose counter enables the appropriate input conditioning on the default source 
and up/down pins for the particular counter (see Table 2-23 and Table 2-29 for definitions of 
the 
default Source
 and 
Up/Down
 pins). The 
GPCTR_Change_Parameter
 function with 
paramID
 = 
ND_SOURCE
 should not be called after a call to 
GPCTR_Change_Parameter
with 
paramID
 = 
ND_INPUT_CONDITIONING
. Corresponding legal values for
 paramValue
are shown below:
•
ND_NONE
—
configures 
default Source
 and 
Up/Down
 pins for no conditioning
•
ND_QUADRATURE_ENCODER_X1
—configures 
default Source 
and 
Up/Down
. Other 
sources cannot be connected in this mode)
•
ND_QUADRATURE_ENCODER_X2
—configures 
default Source
 and 
Up/Down
automatically. Other sources cannot be connected in this mode
•
ND_QUADRATURE_ENCODER_X4
—configures 
default Source
 and 
Up/Down
automatically. Other sources cannot be connected in this mode
•
ND_TWO_PULSE_COUNTING
—configures 
default Source
 and 
Up/Down
 automatically. 
Other sources cannot be connected in this mode