Welding System User Manual
Chapter 2 Function Reference — CTR_EvRead
©
 National Instruments Corporation 2-95 NI-DAQ FRM for PC Compatibles
Using This Function
CTR_EvRead reads the current value of the counter without disturbing the counting process 
and returns the value in count. 
CTR_EvRead also performs overflow detection and returns the 
overflow status in overflow. Overflow detection and the significance of count depend on the 
counter configuration. 
Special Considerations for Overflow Detection
For NI-DAQ to detect an overflow condition, you must configure the counter for TC toggled 
output type and positive output polarity, and then you must configure the counter to stop 
counting on overflow (cont = 0 in the 
CTR_EvCount call). If these conditions are not met, the 
value of overflow is meaningless. If more than one counter is concatenated for event-counting 
applications, you should configure the lower-order counters to continue counting when 
overflow occurs, and overflow detection is only meaningful for the highest order counter. 
count, returned by 
CTR_EvRead for the lower-order counters, then represents the module 
65,536 event count. See Event-Counting Applications in Chapter 3, Software Overview, in the 
NI-DAQ User Manual for PC Compatibles for more information.










