Welding System User Manual
Chapter 2 Function Reference — Config_DAQ_Event_Message
©
 National Instruments Corporation 2-75 NI-DAQ FRM for PC Compatibles
Completed 
operation or 
stopped by 
error
2 Send exactly one message 
when an asynchronous 
operation completes or is 
stopped for an error. chanStr 
indicates the type of channel or 
port, but the actual channel or 
port number is ignored.
MIO devices <AI, AO>
AT-MIO-16D,
AT-MIO-16DE-10 <DIO>
AI devices <AI>
Lab and 1200 Series devices <AI, AO, 
DIO>
AT-AO-6/10 <AO>
516 and LPM devices, 
DAQCard-500/700 <AI>
DSA <AI, AO>
AT-DIO-32F and DIO 6533 devices 
<DIO>
PC-DIO-24/PnP, DAQCard-DIO-24,
PC-DIO-96/PnP, 
DAQPad-6507/6508<DIO>
Voltage out 
of bounds
3 Send a message each time a 
data point from any channel in 
chanStr is outside of the 
voltage region bounded by 
DAQTrigVal0 and 
DAQTrigVal1, where 
DAQTrigVal0 ≥ 
DAQTrigVal1. 
MIO and AI devices <AI>
Lab and 1200 Series devices <AI>
516 and LPM devices, 
DAQCard-500/700 <AI>
Voltage 
within 
bounds
4 Send a message each time a 
data point from any channel in 
chanStr is inside of the voltage 
region bounded by 
DAQTrigVal0 and 
DAQTrigVal1, where 
DAQTrigVal0 ≥ 
DAQTrigVal1. 
MIO and AI devices <AI>
Lab and 1200 Series devices <AI>
516 and LPM devices, 
DAQCard-500/700 <AI>
Table 2-17. 
DAQEvent Messages (Continued)
DAQEvent 
Type
Code
Description
of Message
Usable Devices
<Usable Operation Families>