5.3.2 ALERT HYSTERESIS REGISTER
This device integrates four individually controlled
temperature Alert Hysteresis registers for each alert
output, with a range of 0°C to 255°C.
The alert hysteresis directions are set using bit 3 of the
corresponding Alert Configuration registers
(Register 5-10) to detect rising or falling temperatures.
For rising temperatures, hysteresis range is below the
alert limit where as for falling temperatures, the hyster-
esis range is above the alert limit as shown on
Figure 5-10.
FIGURE 5-10: Graphical Description of Alert Output Hysteresis Direction.
TABLE 5-5: ALERT HYSTERESIS
REGISTERS
Register Register Pointer
Alert 1 Hysteresis – T
HYST1
0000 1100
Alert 2 Hysteresis – T
HYST2
0000 1101
Alert 3 Hysteresis – T
HYST3
0000 1110
Alert 4 Hysteresis – T
HYST4
0000 1111
REGISTER 5-10: ALERT 1, 2, 3 AND 4 HYSTERESIS REGISTER
R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R-0 R-0 R-0
128°C 64°C 32°C 16°C 8°C 4°C 2°C 1°C
bit 7 bit 0
Legend:
R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’
-n = Value at POR ‘1’ = Bit is set 0’ = Bit is cleared x = Bit is unknown
bit 7-0 Alert Hysteresis: Alert Hysteresis range 0x00 to 0xFF, which represents 1°C to 255°C.
cold
Hot
H
y
s
t
e
r
e
s
i
s
cold
Hot
H
y
s
t
e
r
e
s
i
s
T
ALERT
T
HYST
T
ALERT
T
HYST
Rising Temperature
Falling Temperature
Alert Output
ACtive -Low
cold
Hot
H
y
s
t
e
r
e
s
i
s
T
ALERT
T
HYST
Rising Temperature
cold
Hot
H
y
s
t
e
r
e
s
i
s
T
ALERT
T
HYST
Falling Temperature
Alert Output
ACtive -Low
ACtive -High
ACtive -High
Alert Output
Alert Output