Installation Guide

20
W415-0794 / B / 11.03.10
Minimum clearance to combustible construction from appliance and vent surfaces:
Appliance framing: - 6” to top
- 0” to stand-offs
(Rear and sides)
Vent pipe*: - 2” top
- 1” sides and bottom
Recessed depth: - 7”
WITHOUT FRAME INSTALLED
WITH FRAME INSTALLED
5.1 MINIMUM CLEARANCE TO COMBUSTIBLES
2” MIN.*
12” MIN. TO
COMBUSTIBLES
(to ceiling or mantle)
1
1
/2” MIN.
* Any protruding
finishing material
installed in this space
(ie. baseboards) must
leave 2” of
unobstructed clearance
to allow for full rotation
of the control door.
COMBUSTIBLE
NON-COMBUSTIBLE
2”
1”
0” IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK AND
STONE.
BRICK
6” MIN.
FRAME
CONTROL
DOOR (OPEN
POSITION)
* HORIZONTAL VENT SECTIONS: A minimum clearance of 1” at the bottom and sides and 2” at the top of the
vent pipe in all horizontal runs to combustibles is required. Use restop spacer W010-1961 (supplied).
* VERTICAL VENT SECTIONS: A minimum of 1” all around the vent pipe on all vertical runs to combustibles
is required. Use restop spacer W500-0358 (not supplied).