Owners Manual
13
www.napoleongrills.com
7. Reconnect the stainless steel ex connector to the orice and ghten using (2) wrenches.
8. Place the glass tray over the burner and fasten to the pao ame with the screws removed in step 2.
9. A leak test must be performed according to the leak tesng instrucons found in the manual.
Natural Gas Hook-Up
The gas appliance is designed to operate at an inlet pressure of 7 inches water column. The piping up to the
appliance is the responsibility of the installer. A exible metal connector is included to simplify the installaon
of the unit. Connect the exible connector to rigid pipe, copper tube or
an approved exible metal connector, which complies with Z21.4/CSA 6.10.
If using a gas hose (not supplied) connect the ared end of the hose to
the connector on the end of the ex tube as illustrated. Tighten using two
wrenches. (Do not use thread sealer/pipe dope.) Leak test all joints prior
to using the appliance. Piping and valves upstream of the quick disconnect
are not supplied. The gas supply pipe must be suciently sized to supply
the BTU/h specied on the rang plate, based on the length of the piping
run. The quick disconnect must not be installed in an upward direcon and
a readily accessible manual shut-o valve must be installed upstream of,
and as close to, the quick disconnect as is feasible.
Purge the gas supply line of any trapped air prior to the rst ring of the unit.
WARNING!
• The installaon must be performed by a licensed gas er, and all connecons must be leak tested before
operang the grill.
• Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe dope on
any hose connecon.
• Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a re.
• Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject
to accidental damage.
• Leak test all the connecons using a soap and water soluon as per the leak tesng instrucons found in
the manual.