7. Reconnect the stainless steel ex connector to the orice and ghten using (2) wrenches.
8. Place the glass tray over the burner and fasten to the pao ame with the screws removed in step 2.
9. A leak test must be performed according to the leak tesng instrucons found in the manual.
Natural Gas Hook-Up
The gas appliance is designed to operate at an inlet pressure of 7 inches water column. The piping up to the
appliance is the responsibility of the installer. A exible metal connector is included to simplify the installaon
of the unit. Connect the exible connector to rigid pipe, copper tube or
an approved exible metal connector, which complies with Z21.4/CSA 6.10.
If using a gas hose (not supplied) connect the ared end of the hose to
the connector on the end of the ex tube as illustrated. Tighten using two
wrenches. (Do not use thread sealer/pipe dope.) Leak test all joints prior
to using the appliance. Piping and valves upstream of the quick disconnect
are not supplied. The gas supply pipe must be suciently sized to supply
the BTU/h specied on the rang plate, based on the length of the piping
run. The quick disconnect must not be installed in an upward direcon and
a readily accessible manual shut-o valve must be installed upstream of,
and as close to, the quick disconnect as is feasible.
Purge the gas supply line of any trapped air prior to the rst ring of the unit.
WARNING!
The installaon must be performed by a licensed gas er, and all connecons must be leak tested before
operang the grill.
Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe dope on
any hose connecon.
Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a re.
Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject
to accidental damage.
Leak test all the connecons using a soap and water soluon as per the leak tesng instrucons found in
the manual.