INPUT
MODEL FUEL MAX. INPUT Btu/Hr
GPFR60
GPFS60
Natural Gas 60, 000
GPFR60
GPFS60
Propane Gas 60, 000
GAS INLET PRESSURES
NATURAL PROPANE
Maximum Inlet Pressure 7.0" w.c. 11.0" w.c.
MINIMUM CLEARANCE TO COMBUSTIBLES
INCHES MM
Side Walls 24 610
Top of unit to ceiling 72 1830
Floor 9 229
72”
(1829mm)
CENTRE OF PATIOFLAME
24”
(610mm)
24”
(610mm)
MAXIMUM
OVERHANG
9”
(229mm)
N415-0310 Jan 11.19.indd 6 11/01/2019 2:10:39 PM